A Rapid 3D Partial-Fourier PRESTO-SENSE Method for Functional Motor MRI

نویسندگان

  • M. Klarhöfer
  • B. Dilharreguy
  • C. T. Moonen
چکیده

Introduction: High temporal resolution is necessary for an accurate determination of the hemodynamic response to functional stimuli [1]. At the same time high volume coverage is desirable to allow an examination of temporal relations between different brain regions involved in performing a task. Partial-Fourier PRESTO-SENSE [2] seems to be a good candidate for event related fMRI studies because it combines whole brain acquisition with a volume repetition rate of 2 Hz. The functional paradigm used in this study consisted of a task involving brain areas responsible for planning, organization and motor execution as well as the visual system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series.

A 3D sequence for dynamic susceptibility imaging is proposed which combines echo-shifting principles (such as PRESTO), sensitivity encoding (SENSE), and partial-Fourier acquisition. The method uses a moderate SENSE factor of 2 and takes advantage of an alternating partial k-space acquisition in the "slow" phase encode direction allowing an iterative reconstruction using high-resolution phase es...

متن کامل

The PRESTO technique for fMRI

In the early days of BOLD fMRI, the acquisition of T(2)(*) weighted data was greatly facilitated by rapid scan techniques such as EPI. The latter, however, was only available on a few MRI systems that were equipped with specialized hardware that allowed rapid switching of the imaging gradients. For this reason, soon after the invention of fMRI, the scan technique PRESTO was developed to make ra...

متن کامل

A Multi-Resolution Comparison of Single-Shot EPI, 3DFFE and PRESTO for fMRI at 7T

INTRODUCTION Single-shot Echo-Planar Imaging (EPI) is the sequence most commonly used for fMRI experiments. At high field, e.g. 7T, magnetic field inhomogeneities cause spins to become out of phase quickly, and distortion and signal dropout become severe [1]. Consequently, single-shot EPI fMRI suffers technical limitations at high field. Here we consider two alternatives to EPI for high field f...

متن کامل

Multi-Echo PRESTO: T2* mapping for 3D fMR1

Introduction Last year the Dual-Echo PRESTO [l] technique was introduced to measure I0 and T2* simultaneously. This technique is an extension of the PRESTO [2] technique (TE > TR) and allows for the acquisition of two echoes within each TR. The first echo with a short TE (-7 ms) is acquired directly after RF excitation and is immediately followed by an echo with a long TE (-43 ms) which is echo...

متن کامل

On The Simulation of Partial Differential Equations Using the Hybrid of Fourier Transform and Homotopy Perturbation Method

In the present work, a hybrid of Fourier transform and homotopy perturbation method is developed for solving the non-homogeneous partial differential equations with variable coefficients. The Fourier transform is employed with combination of homotopy perturbation method (HPM), the so called Fourier transform homotopy perturbation method (FTHPM) to solve the partial differential equations. The c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002