Complication Rates With Human Acellular Dermal Matrices: Retrospective Review of 211 Consecutive Breast Reconstructions

نویسندگان

  • Robert H. Schnarrs
  • Claire M. Carman
  • Chase Tobin
  • Serena A. Chase
  • Kerri A. Rossmeier
چکیده

BACKGROUND Human acellular dermal matrix (HADM) is commonly used to provide coverage and support for breast reconstruction. The primary purpose of this study was to evaluate the complication rates associated with breast reconstruction procedures when performed in conjunction with multiple types of HADM in a consecutive series. METHODS After receiving institutional review board approval, medical records from a single surgeon were retrospectively reviewed for 126 consecutive patients (170 breasts and 211 procedures) who received a breast reconstruction or revision with implantation of HADM between 2012 and 2014. Patient demographics, surgical technique, and the complication profile of 4 major types of HADM were evaluated by procedure. Complication data were primarily evaluated for infection, seroma formation, necrosis, and other complications requiring additional surgery. RESULTS The total complication rate was 19.4%. The complication rates were not statistically different between all 4 types of HADM: Alloderm (n = 143); Alloderm RTU (n = 19); FlexHD (n = 18); hMatrix (n = 32) (P > 0.05). Smokers and large-breasted women (≥500 g) had a significantly higher complication rate than the rest of the population (P < 0.01 and P < 0.03, respectively). The complication rates associated with all other patient cohorts analyzed (age, body mass index, comorbid conditions, cancer diagnosis, prepectoral technique) showed no influence on complication rates (P > 0.05). CONCLUSIONS In characteristically similar cohorts, there was no statistically significant difference in complication rates based on type of HADM; however, certain risk factors and anatomy should be considered before HADM-assisted breast reconstruction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Head-to-head Comparison between SurgiMend and Epiflex in 127 Breast Reconstructions

BACKGROUND The use of acellular dermal matrices (ADM) has become a widely used option in breast reconstruction. A great deal of literature is available, totaling over 2400 ADM reconstructions. Nonetheless, head-to-head comparisons between SurgiMend and Epiflex are not yet reported. In fact, this is the first clinical data report on the use of Epiflex. This work will, therefore, compare postoper...

متن کامل

The Scarless Latissimus Dorsi Flap Provides Effective Lower Pole Prosthetic Coverage in Breast Reconstruction

BACKGROUND The evolution of surgical breast cancer treatment has led to the oncologically safe preservation of greater amounts of native skin, yet we are still often using flaps with large skin paddles, thereby resulting in significant donor-site scars. This explains the increasing appeal of acellular dermal matrix reconstructions. Acellular dermal matrices can, however, have significant proble...

متن کامل

Does Acellular Dermal Matrix Thickness Affect Complication Rate in Tissue Expander Based Breast Reconstruction?

Background. While the benefits of using acellular dermal matrices (ADMs) in breast reconstruction are well described, their use has been associated with additional complications. The purpose of this study was to determine if ADM thickness affects complications in breast reconstruction. Methods. A retrospective chart review was performed including all tissue expander based breast reconstructions...

متن کامل

Evaluation of Complication Rates after Breast Surgery Using Acellular Dermal Matrix: Median Follow-Up of Three Years

INTRODUCTION Acellular dermal matrices (ADMs) are now commonly used for breast reconstruction surgery. There are various products available: ADMs derived from human (HADM), porcine (PADM), or bovine (BADM) sources. Detailed long-term follow-up studies are necessary to detect differences in complication rates between these products. MATERIAL AND METHODS From 2010 to 2015, forty-one patients un...

متن کامل

Complication prevalence following use of tutoplast-derived human acellular dermal matrix in prosthetic breast reconstruction: a retrospective review of 203 patients.

Use of human acellular dermal matrix (ADM) during prosthetic breast reconstruction has increased. Several ADM products are available produced by differing manufacturing techniques. It is not known if outcomes vary with different products. This study reports the complication prevalence following use of a tutoplast-derived ADM (T-ADM) in prosthetic breast reconstruction. We performed a retrospect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016