Determination of phthalates in water using fiber introduction mass spectrometry.

نویسندگان

  • Rogério C Silva
  • Eduardo C Meurer
  • Marcos N Eberlin
  • Fabio Augusto
چکیده

Fiber introduction mass spectrometry (FIMS)-a direct coupling of SPME and MS-using selective ion monitoring (SIM) was used to detect and quantify dimethylphthalate (DMP), diethylphthalate (DEP) and dipropylphthalate (DPP) in mineral water. In FIMS, a chromatographic silicone septum is the only barrier between ambient and the high-vacuum mass spectrometer, permitting direct introduction of the SPME fiber into the ionization region of the equipment. After their thermal desorption and ionization and dissociation, the extracted phthalates are detected and quantitated by MS. Three types of SPME fibers were screened for best analyte sorption/desorption behaviors: 100 microm polydimethylsiloxane (PDMS), 65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) and 65 microm Carbowax/divinylbenzene (CW/DVB). The PDMS/DVB and CW/DVB fibers were then evaluated for precision, and quantitative figures of merit were assessed for extractions using the PDMS/DVB fiber, which displayed the best overall performance. FIMS with the PDMS/DVB fiber allows simple extraction and MS detection and quantitation of DMP in water with good linearity and precision, and at concentrations as low as 3.6 microg L(-1). The LD and LQ of FIMS are below the maximum phthalate concentration allowed by the USEPA for drinking water (6 microg L(-1)).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HCl- Etched Steel Fiber for Determination of Phthalates in Water Samples by Solid-Phase Microextraction

In the present work, a stainless steel wire was etched by hydrochloric acid during a chemical etching process. The obtained black layer on the surface of the fiber was used as sorbent for extraction of trace amount of phthalates in the aqueous samples by solid phase microextraction. New fiber efficiency was investigated using a home-made solid-phase microextraction (SPME) device and gas chr...

متن کامل

Development and validation of a method for the determination of trace alkylphenols and phthalates in sea water and air using GC-MS

An analytical method has been developed for the simultaneous extraction and determination of trace tertiary octylphenol (t-OP), technical nonylphenol isomers (NP), nonylphenol monoethoxylate isomers (NP1EO) and seven phthalates in sea water and the atmosphere using gas chromatography-mass spectrometry (GC-MS). Large volume samples were collected using a modified in-situ pump equipped with a PAD...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

A Developed Electromembrane Technique Based on Flat Electrospun Membrane Coupled with Gas-chromatography for the Determination of Phthalates in Different Water Samples

In this work, we successfully developed electromembrane extraction via preparation of an electrospun flat membrane based on device. The polyurethane-membrane was prepared by electrospinning method and used in EME. Affecting parameters on membrane preparation were optimized by Taguchi design. The developed method was used for extraction of phthalates as typical molecules and the proposed method ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 130 2  شماره 

صفحات  -

تاریخ انتشار 2005