Reference values for Doppler ultrasound parameters of the thyroid in a healthy iodine-non-deficient population.
نویسندگان
چکیده
The aim of this study was to describe normal Doppler parameter values in the thyroid arteries in an iodine-replete region. 165 individuals were randomly selected in a community located in the south-east of Brazil. We obtained a clinical history on each subject and determined serum thyrotropin, antiperoxidase antibodies, thyrotropin receptor antibody (TRAb) and thyroid volumes through ultrasound. Subjects with thyroid disease and those under 20 years of age were excluded. 84 representative subjects (30 men and 54 women) remained. The systolic peak velocity (SPV), resistive index (RI) and pulsatility index (PI) in the superior and inferior thyroid arteries were measured using a 5-12 MHz linear probe. Except for the RI, the distribution of all Doppler parameters was non-gaussian. The median and mean references for the SPV, RI and PI were 24.80 cm s(-1) and 25.85 cm s(-1), 0.60 and 0.62, and 0.98 and 1.04, respectively, for superior thyroid arteries; these reference values for the inferior thyroid artery were 20.92 cm s(-1) and 21.50 cm s(-1), 0.57 and 0.57, and 0.84 and 0.88, respectively (p<0.001). Women had greater SPV values (p<0.01). We have determined reference thyroid Doppler parameter values in our iodine-non-deficient population and prepared tables by sex and age.
منابع مشابه
Reference intervals of serum thyroid function tests in a previously iodine-deficient area.
AIM We undertook the present study to establish reference data for serum thyroid function tests in a previously iodine-deficient area. METHODS Data from 4298 individuals, 20-79 years of age were available for the present analysis. Thyroid function (thyrotropin [TSH], free triiodothyronine [FT(3)], and free thyroxine [FT(4)]) and serum autoantibodies to thyroperoxidase (anti-TPOAb) were evalua...
متن کاملStudy of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat
Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...
متن کاملLocal versus WHO/International Council for Control of Iodine Deficiency Disorders-recommended thyroid volume reference in the assessment of iodine deficiency disorders.
OBJECTIVE Iodine deficiency endemia is defined by the goitre prevalence and the median urinary iodine concentration in a population. Lack of local thyroid volume reference data may bring many health workers to use the European-based WHO/International Council for Control of Iodine Deficiency Disorders (ICCIDD)-recommended reference for the assessment of goitre prevalence in children in different...
متن کاملNon-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis
In this study, a method for non-invasive estimation of stress on the heart wall in the diastole phase is presented using ultrasound echocardiography and tissue Doppler imaging. The aim of this study was to evaluate the stress on the heart wall as a pre-diagnosis to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...
متن کاملاثر مکمل یاری ید بر حجم تیروئید و هورمون محرک تیروئید( TSH )زنان غیر باردار استان آذربایجان غربی
Background & Aims: Iodine as an essential element is required for biosynthesis of thyroid hormones as well as for the development of the nervous system of the fetus. Therefore, the consumption of an extra dose of iodine ranging from 150-250 µg/day has been recommended for women planning a pregnancy or at early stage of maternity by world health organizations. This study was designed to evaluate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of radiology
دوره 80 956 شماره
صفحات -
تاریخ انتشار 2007