Estimation of Intraocular Lens Power Calculation after Myopic Corneal Refractive Surgery: Using Corneal Height in Anterior Segment Optical Coherence Tomography

نویسندگان

  • Dong Hyun Kim
  • Mee Kum Kim
  • Won Ryang Wee
چکیده

PURPOSE To investigate the feasibility of estimating effective lens position (ELP) and calculating intraocular lens power using corneal height (CH), as measured using anterior segment optical coherence tomography (AS-OCT), in patients who have undergone corneal refractive surgery. METHODS This study included 23 patients (30 eyes) who have undergone myopic corneal refractive surgery and subsequent successful cataract surgery. The CH was measured with AS-OCT, and the measured ELP (ELPm) was calculated. Intraocular lens power, which could achieve actual emmetropia (Preal), was determined with medical records. Estimated ELP (ELPest) was back-calculated using Preal, axial length, and keratometric value through the SRK/T formula. After searching the best-fit regression formula between ELPm and ELPest, converted ELP and intraocular lens power (ELPconv, Pconv) were obtained and then compared to ELPest and Preal, respectively. The proportion of eyes within a defined error was investigated. RESULTS Mean CH, ELPest, and ELPm were 3.71 ± 0.23, 7.74 ± 1.09, 5.78 ± 0.26 mm, respectively. The ELPm and ELPest were linearly correlated (ELPest = 1.841 × ELPm - 2.018, p = 0.023, R = 0.410) and ELPconv and Pconv agreed well with ELPest and Preal, respectively. Eyes within ±0.5, ±1.0, ±1.5, and ±2.0 diopters of the calculated Pconv, were 23.3%, 66.6%, 83.3%, and 100.0%, respectively. CONCLUSIONS Intraocular lens power calculation using CH measured with AS-OCT shows comparable accuracy to several conventional methods in eyes following corneal refractive surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبه‌ی لنز داخل چشمی افراد با قرنیه‌ی طبیعی

Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...

متن کامل

Intraocular lens power calculation after myopic and hyperopic laser vision correction using optical coherence tomography.

PURPOSE To use optical coherence tomography (OCT) to measure corneal power and calculate intraocular lens (IOL) power in cataract surgeries after myopic and hyperopic laser vision correction (LVC). METHODS Patients with previous LVC were enrolled in this prospective study at two centers (Doheny Eye Institute, Los Angeles, CA, USA and Cullen Eye Institute, Houston, TX, USA). Corneal power was ...

متن کامل

Case of late-onset corneal decompensation after iris-fixated phakic intraocular lens implantation.

A 48-year-old myopic patient with bilateral anterior chamber depth of 3.1 mm and endothelial cell density (ECD) of 2525 cells/mm(2) and 2638 cells/mm(2) preoperatively had bilateral implantation of an Artisan iris-fixated phakic intraocular lens (pIOL). Five years postoperatively, unilateral corneal stromal edema was seen in a circumscribed area overlying the temporal ridge of the pIOL in the r...

متن کامل

Total corneal power estimation: ray tracing method versus gaussian optics formula.

PURPOSE To evaluate with the use of corneal topographic data the differences between total corneal power calculated using ray tracing (TCP) and the Gaussian formula (GEP) in normal eyes, eyes that previously underwent laser in situ keratomileusis/photorefractive keratectomy (LASIK/PRK), and theoretical models. METHODS TCP and GEP using mean instantaneous curvature were calculated over the cen...

متن کامل

Influence of anterior chamber morphometrics on endothelial cell changes after phakic intraocular lens implantation.

PURPOSE To analyze the position of iris-fixated phakic intraocular lenses (pIOLs) using anterior segment optical coherence tomography (AS-OCT) and evaluate the effect of anterior chamber morphometrics on endothelial cell changes. SETTING Department of Ophthalmology, Academic Hospital Maastricht, The Netherlands. METHODS In this cross-sectional study, AS-OCT was used to measure the distances...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 29  شماره 

صفحات  -

تاریخ انتشار 2015