Ultrahigh temporal resolution dynamic imaging of He-3 MRI using bolus delivery
نویسندگان
چکیده
R. L. O'Halloran, J. H. Holmes, E. T. Peterson, R. L. Sorkness, M. L. Schiebler, and S. B. Fain Medical Physics, University of Wisconsin, Madison, WI, United States, Applied Science Laboratory, GE Healthcare, Waukesha, WI, United States, Biomedical Engineering, University of Wisconsin, Madison, WI, United States, School of Pharmacy, University of Wisconsin, Madison, WI, United States, Radiology, University of Wisconsin, Madison, WI, United States
منابع مشابه
3D Dynamic Contrast-Enhanced Using Undersampled Golden-Radial Phase Encoding
INTRODUCTION: 3D Time-Resolved Dynamic Contrast Enhanced MRI (DCE-MRI) is an important tool to depict anatomic and dynamic information (bolus pass) of thoracic vessels. The current limitation of this application is the requirement of both high spatial and temporal resolution. Several methods have been proposed to overcome this problem [1-3], however, these techniques usually need an accurate ti...
متن کاملAutomatic Bolus Analysis for DCE-MRI Using Radial Golden-Angle Stack-of-stars GRE Imaging
INTRODUCTION: In clinical 3D Dynamic Contrast-Enhanced MRI (DCE-MRI) of the abdomen, multiple phases of perfusion (pre-contrast, arterial, venous, delayed phases) are captured subsequently in breath-hold scans. Novel imaging and reconstruction techniques such as GRASP promise DCEMRI at a temporal resolution of only few seconds from a single, continuous image acquisition. This reduces the requir...
متن کاملDiagnostic value of CT and MRI of Temporal Bone in Cochlear Implantation Candidates
Background Cochlear implantation is an approved treatment which can be used to treat severe to profound hearing loss. Imaging before cochlear implant surgery is very important in decision making and assessing the temporal bone anatomy for surgery. We aimed to assess the diagnostic value of high resolution CT scan (HRCT), and MRI of temporal bone in candidate pati...
متن کاملQuantitative myocardial perfusion imaging using a step arterial-input function
Background Modern MRI myocardial perfusion protocols use rapid venous bolus injections, typically 3-5 ml/s of 5-15 ml of agent over a few seconds. The resulting arterial input functions are rapidly varying with high agent concentrations (Fig. 1A and 1B) and thus typically require high temporal resolution acquisitions (~1 sec), custom pulse sequences and complex processing methods for perfusion ...
متن کاملMagnetic Particle Imaging for High Temporal Resolution Assessment of Aneurysm Hemodynamics
PURPOSE The purpose of this work was to demonstrate the capability of magnetic particle imaging (MPI) to assess the hemodynamics in a realistic 3D aneurysm model obtained by additive manufacturing. MPI was compared with magnetic resonance imaging (MRI) and dynamic digital subtraction angiography (DSA). MATERIALS AND METHODS The aneurysm model was of saccular morphology (7 mm dome height, 5 mm...
متن کامل