Reducing wastage of inhalation anesthetics using real-time decision support to notify of excessive fresh gas flow.

نویسندگان

  • Bala G Nair
  • Gene N Peterson
  • Moni B Neradilek
  • Shu Fang Newman
  • Elaine Y Huang
  • Howard A Schwid
چکیده

BACKGROUND Reduced consumption of inhalation anesthetics can be safely achieved by reducing excess fresh gas flow (FGF). In this study the authors describe the use of a real-time decision support tool to reduce excess FGF to lower, less wasteful levels. METHOD The authors applied a decision support tool called the Smart Anesthesia Manager™ (University of Washington, Seattle, WA) that analyzes real-time data from an Anesthesia Information Management System to notify the anesthesia team if FGF exceeds 1 l/min. If sevoflurane consumption reached 2 minimum alveolar concentration-hour under low flow anesthesia (FGF < 2 l/min), a second message was generated to increase FGF to 2 l/min, to comply with Food and Drug Administration guidelines. To evaluate the tool, mean FGF between surgical incision and the end of procedure was compared in four phases: (1) a baseline period before instituting decision rules, (2) Intervention-1 when decision support to reduce FGF was applied, (3) Intervention-2 when the decision rule to reduce flow was deliberately inactivated, and (4) Intervention-3 when decision rules were reactivated. RESULTS The mean ± SD FGF reduced from 2.10 ± 1.12 l/min (n = 1,714) during baseline to 1.60 ± 1.01 l/min (n = 2,232) when decision rules were instituted (P < 0.001). When the decision rule to reduce flow was inactivated, mean FGF increased to 1.87 ± 1.15 l/min (n = 1,732) (P < 0.001), with an increasing trend in FGF of 0.1 l/min/month (P = 0.02). On reactivating the decision rules, the mean FGF came down to 1.59 ± 1.02 l/min (n = 1,845). Through the Smart Anesthesia Messenger™ system, the authors saved 9.5 l of sevoflurane, 6.0 l of desflurane, and 0.8 l isoflurane per month, translating to an annual savings of $104,916. CONCLUSIONS Real-time notification is an effective way to reduce inhalation agent usage through decreased excess FGFs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sustaining a reduction in fresh gas flow rates.

In Reply: We sincerely appreciate the comments by Drs. Kennedy and French related to our study1 aimed at reducing fresh gas flow (FGF) by using a decision support system. We believe that continuous feedback of information is necessary to maintain desired provider behavior and care patterns. This is supported by our finding that when we turned off the FGF reminders, the providers reverted to use...

متن کامل

ECT and LS-SVM Based Void Fraction Measurement of Oil-Gas Two-Phase Flow

A method based on Electrical Capacitance Tomography (ECT) and an improved Least Squares Support Vector Machine (LS-SVM) is proposed for void fraction measurement of oil-gas two-phase flow. In the modeling stage, to solve the two problems in LS-SVM, pruning skills are employed to make LS-SVM sparse and robust; then the Real-Coded Genetic Algorithm is introduced to solve the difficult problem...

متن کامل

Breathing systems: effect of fresh gas flow rate on enflurane consumption.

The vaporization rates of enflurane were measured in 412 anaesthetics using appropriate fresh gas flow rates in Bain (12 litre min-1), Magill (6 litre min-1) and circle systems (3 litre min-1, 1 litre min-1 and "closed"). In all patients reducing the fresh gas flow rate resulted in lower enflurane consumption. The percent savings were 18-86% depending on the initial fresh gas flow rate and the ...

متن کامل

Pseudo Steady State Gas Flow in Tight Reservoir under Dual Mechanism Flow

Gas reservoirs with low permeability (k<0.1 mD) are among the unconventional reservoirs and are commonly termed as "Tight Gas Reservoirs". In conventional gas reservoirs that have high permeability, the flow of gas is basically controlled by the reservoir permeability and it is calculated using the Darcy equation. In these reservoirs, gas flow due to gas diffusion is ignored compared to Dar...

متن کامل

Incidence of Anesthetic Awareness may be Higher in Low Flow Anesthesia

There is a growing interest in applying techniques of low flow anesthesia in different groups of surgical patients. Numerous studies confirm the benefits of low flow anesthesia in comparison to anesthesia with high flow, whereby its limitation and disadvantages have been addressed. The main advantages of low-flow anesthesia techniques involve three areas: pulmonary-anesthesia with low fresh gas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 118 4  شماره 

صفحات  -

تاریخ انتشار 2013