Diagnosis of Nerve Root Compromise of the Lumbar Spine: Evaluation of the Performance of Three-dimensional Isotropic T2-weighted Turbo Spin-Echo SPACE Sequence at 3T

نویسندگان

  • Jinkyeong Sung
  • Won-Hee Jee
  • Joon-Yong Jung
  • Jinhee Jang
  • Jin-Sung Kim
  • Young-Hoon Kim
  • Kee-Yong Ha
چکیده

OBJECTIVE To explore the performance of three-dimensional (3D) isotropic T2-weighted turbo spin-echo (TSE) sampling perfection with application optimized contrasts using different flip angle evolution (SPACE) sequence on a 3T system, for the evaluation of nerve root compromise by disc herniation or stenosis from central to extraforaminal location of the lumbar spine, when used alone or in combination with conventional two-dimensional (2D) TSE sequence. MATERIALS AND METHODS Thirty-seven patients who had undergone 3T spine MRI including 2D and 3D sequences, and had subsequent spine surgery for nerve root compromise at a total of 39 nerve levels, were analyzed. A total of 78 nerve roots (48 symptomatic and 30 asymptomatic sites) were graded (0 to 3) using different MRI sets of 2D, 3D (axial plus sagittal), 3D (all planes), and combination of 2D and 3D sequences, with respect to the nerve root compromise caused by posterior disc herniations, lateral recess stenoses, neural foraminal stenoses, or extraforaminal disc herniations; grading was done independently by two readers. Diagnostic performance was compared between different imaging sets using the receiver operating characteristics (ROC) curve analysis. RESULTS There were no statistically significant differences (p = 0.203 to > 0.999) in the ROC curve area between the imaging sets for both readers 1 and 2, except for combined 2D and 3D (0.843) vs. 2D (0.802) for reader 1 (p = 0.035), and combined 2D and 3D (0.820) vs. 3D including all planes (0.765) for reader 2 (p = 0.049). CONCLUSION The performance of 3D isotropic T2-weighted TSE sequence of the lumbar spine, whether axial plus sagittal images, or all planes of images, was not significantly different from that of 2D TSE sequences, for the evaluation of nerve root compromise of the lumbar spine. Combining 2D and 3D might possibly improve the diagnostic accuracy compared with either one.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lumbar degenerative disk disease: prospective comparison of conventional T2-weighted spin-echo imaging and T2-weighted rapid acquisition relaxation-enhanced imaging.

PURPOSE To compare conventional T2-weighted spin-echo imaging with a rapid acquisition relaxation enhanced (RARE) technique in the routine evaluation of lumbar degenerative disk disease. METHODS Thirty consecutive patients referred for evaluation of the lumbar spine for suspected degenerative disk disease were evaluated with sagittal and axial T1-weighted spin-echo, conventional T2-weighted s...

متن کامل

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

Sequential MR imaging of denervated muscle: experimental study.

BACKGROUND AND PURPOSE MR changes in denervated muscles have been reported to occur within days up to several weeks after peripheral nerve damage. The purpose of this experimental study was to investigate the longitudinal changes in denervated muscles by using MR imaging. METHODS In 12 Lewis rats, the left sciatic nerve was transected at the level of the proximal thigh. MR imaging of both leg...

متن کامل

T2-weighted three-dimensional turbo spin-echo MR of intracranial aneurysms.

A T2-weighted three-dimensional turbo spin-echo sequence is described that accurately depicted the anatomy of 18 intracranial aneurysms in 10 patients.

متن کامل

Reduction in Artifacts in the Liver at 3T Using a 3D T2-Weighted Variable Flip-Angle Sequence (SPACE)

Introduction: 3T MRI systems provide an inherent increase in SNR that can be used for gains in spatial and/or temporal resolution. However, a limitation of imaging at 3T is an increase in specific absorption rate (SAR), particularly in sequences with large flip angles and many refocusing pulses, as occurs with many 180o refocusing pulses of a turbo spin echo sequence. A recently developed seque...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017