Inter-frame Motion Correction for MR Thermometry
نویسندگان
چکیده
Noninvasive temperature measurement is feasible with MRI to monitor changes in thermal therapy. Phase shift based MR thermometry gives an estimate of the relative temperature variation between thermal and baseline images. This technique is limited, however, when applied on targets under inter-frame motion. Simple image registration and subtraction are not adequate to recover the temperature properly since the phase shift due to temperature changes is corrupted by an unwanted phase shift. In this work, the unwanted phase shift is predicted from the raw registered phase shift map itself. To estimate the unwanted phase shift, a thin plate smoothing spline is fitted to the values outside the heated region. The spline value in the heated area serves as an estimate for the offset. The estimation result is applied to correct errors in the temperature maps of an ex-vivo experiment.
منابع مشابه
Real-time MR-thermometry and dosimetry for interventional guidance on abdominal organs.
The use of proton resonance frequency shift-based magnetic resonance (MR) thermometry for interventional guidance on abdominal organs is hampered by the constant displacement of the target due to the respiratory cycle and the associated thermometry artifacts. Ideally, a suitable MR thermometry method should for this role achieve a subsecond temporal resolution while maintaining a precision comp...
متن کاملMagnetic resonance thermal imaging combined with SMASH navigators in the presence of motion
This study develops and tests an MR thermometry method combined with SMASH navigators in phantom experiments mimicking human liver motion with the purpose of detecting and correcting motion artifacts in thermal MR images. Experimental data were acquired on a 3T MRI scanner. Motion artifacts of mobile phantoms mimicking human liver motion were detected and corrected using the SMASH navigators an...
متن کاملFeasibility of MR-thermometry with blood suppression on the human heart at 3T
Introduction Ventricular tachycardia and atrial fibrillation can be treated in a minimally invasive fashion with localized catheter radio-frequency ablation of the myocardium [1]. For cardiac ablation, PRFS-based MR thermometry [2] may provide intra-procedural feedback, helping with the determination of the therapy endpoint and to avoid damage to adjacent vital structures such as the esophagus....
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملPRF based MR-Thermometry on Abdominal Organs: A pragmatic comparison of referenceless vs multi-baseline
Introduction Reliable temperature and thermal-dose measurements using PRF based MR-thermometry for MR-guided ablation therapy on abdominal organs are complicated by the fact that the target moves through an inhomogeneous and time-variant magnetic field. Two correction approaches emerged recently as the most promising candidates to allow continuous real-time MR-thermometry under free-breathing c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 8 Pt 1 شماره
صفحات -
تاریخ انتشار 2005