Lower periprosthetic bone loss and good fixation of an ultra-short stem compared to a conventional stem in uncemented total hip arthroplasty

نویسندگان

  • Mats Salemyr
  • Olle Muren
  • Torbjörn Ahl
  • Henrik Bodén
  • Thomas Eisler
  • André Stark
  • Olof Sköldenberg
چکیده

BACKGROUND AND PURPOSE We hypothesized that an ultra-short stem would load the proximal femur in a more physiological way and could therefore reduce the adaptive periprosthetic bone loss known as stress shielding. PATIENTS AND METHODS 51 patients with primary hip osteoarthritis were randomized to total hip arthroplasty (THA) with either an ultra-short stem or a conventional tapered stem. The primary endpoint was change in periprosthetic bone mineral density (BMD), measured with dual-energy x-ray absorptiometry (DXA), in Gruen zones 1 and 7, two years after surgery. Secondary endpoints were change in periprosthetic BMD in the entire periprosthetic region, i.e. Gruen zones 1 through 7, stem migration measured with radiostereometric analysis (RSA), and function measured with self-administered functional scores. RESULTS The periprosthetic decrease in BMD was statistically significantly lower with the ultra-short stem. In Gruen zone 1, the mean difference was 18% (95% CI: -27% to -10%). In zone 7, the difference was 5% (CI: -12% to -3%) and for Gruen zones 1-7 the difference was also 5% (CI: -9% to -2%). During the first 6 weeks postoperatively, the ultra-short stems migrated 0.77 mm more on average than the conventional stems. 3 months after surgery, no further migration was seen. The functional scores improved during the study and were similar in the 2 groups. INTERPRETATION Up to 2 years after total hip arthroplasty, compared to the conventional tapered stem the ultra-short uncemented anatomical stem induced lower periprosthetic bone loss and had equally excellent stem fixation and clinical outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-Short Versus Conventional Uncemented Stems for Hip Replacement in Octogenarians.

The aim of this study was to determine how an ultra-short anatomic uncemented stem vs a diaphyseal filling five-eighths porous coated uncemented femoral stem (conventional stem) affects the survival of primary total hip arthroplasties in octogenarians. The current study consisted of 52 patients (55 hips) in the ultra-short stem group (mean age, 85.5±5.3 years) and 61 patients (72 hips) in the d...

متن کامل

Periprosthetic bone mineral density and fixation of the uncemented CLS stem related to different weight bearing regimes

BACKGROUND AND PURPOSE There is no consensus on the best rehabilitation regime after uncemented total hip arthroplasty. Theoretically, bone ingrowth into the implant should benefit from initial partial weight bearing. We investigated whether the degree of postoperative weight bearing influences the periprosthetic bone mineral density (BMD) and/or the stability of the CLS stem. PATIENTS AND ME...

متن کامل

Progressive femoral cortical and cancellous bone density loss after uncemented tapered-design stem fixation

BACKGROUND Aseptic implant loosening and periprosthetic bone loss are major problems after total hip arthroplasty (THA). We present an in vivo method of computed tomography (CT) assisted osteodensitometry after THA that differentiates between cortical and cancellous bone density (BD) and area around the femoral component. METHOD Cortical and cancellous periprosthetic femoral BD (mg CaHA/mL), ...

متن کامل

Epidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience.

AIMS The goals of this study were to define the risk factors, characteristics, and chronology of fractures in 5417 revision total hip arthroplasties (THAs). PATIENTS AND METHODS From our hospital's prospectively collected database we identified all patients who had undergone a revision THA between 1969 and 2011 which involved the femoral stem. The patients' medical records and radiographs wer...

متن کامل

Good stability but high periprosthetic bone mineral loss and late-occurring periprosthetic fractures with use of uncemented tapered femoral stems in patients with a femoral neck fracture

BACKGROUND AND PURPOSE We previously evaluated a new uncemented femoral stem designed for elderly patients with a femoral neck fracture and found stable implant fixation and good clinical results up to 2 years postoperatively, despite substantial periprosthetic bone mineral loss. We now present the medium-term follow-up results from this study. PATIENTS AND METHODS In this observational prosp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 86  شماره 

صفحات  -

تاریخ انتشار 2015