Catheter ablation of atrioventricular junction using radiofrequency current in 17 patients. Comparison of standard and large-tip catheter electrodes.

نویسندگان

  • W M Jackman
  • X Z Wang
  • K J Friday
  • D M Fitzgerald
  • C Roman
  • K Moulton
  • P D Margolis
  • A J Bowman
  • K H Kuck
  • G V Naccarelli
چکیده

BACKGROUND Two catheter electrode systems were compared for delivering radiofrequency current for ablation of the atrioventricular junction. Seventeen patients with drug-resistant supraventricular tachyarrhythmias were studied. METHODS AND RESULTS A 6F or 7F catheter with six or eight standard electrodes (1.25 mm wide, 2.5-mm spacing) was used in the first seven patients (group 1). A 7F quadripolar catheter with a large-tip electrode (4 mm long; surface area, 27 mm2) was used in the final 10 patients (group 2). Both ablation catheters were positioned to record a large atrial potential and a small but sharp His bundle potential from the distal bipolar electrode pair. Radiofrequency current was applied between a large skin electrode on the left posterior chest and either 1) each individual electrode on the standard-tip electrode catheter at 40 V (group 1) or 2) the large-tip electrode at 50-60 V (group 2). Radiofrequency current was limited to 40 V in group patients because of the strong potential for an early impedance rise when higher voltage is applied through standard electrodes. Complete atrioventricular block was achieved in six of seven group 1 patients and all 10 group 2 patients. A junctional escape rhythm followed ablation in five or six group 1 patients (mean cycle length, 1,066 +/- 162 msec) and eight of 10 group 2 patients (mean cycle length, 1,281 +/- 231 msec). Atrioventricular block was produced in a mean of 4.7 +/- 4.6 radiofrequency current applications delivered over a period of 42 +/- 45 minutes using the large-tip electrode (group 2) compared with 46 +/- 22 applications using standard electrodes (15.9 +/- 10.2 applications delivered through the standard-tip electrode) over a period of 147 +/- 59 minutes (group 1). For the application producing atrioventricular block, the large-tip electrode used higher voltage (58 +/- 17 versus 38 +/- 5 V, p less than 0.03) and had lower impedance (103 +/- 22 versus 148 +/- 40 omega, p less than 0.01), resulting in greater power (33.0 +/- 13.0 versus 10.2 +/- 0.6 W, p less than 0.003) and shorter time to block (8 +/- 3 versus 22 +/- 3 seconds, p less than 0.001). Current delivery through standard electrodes was limited by an impedance rise occurring 7 +/- 7 seconds after the onset of one or more radiofrequency current applications at 10 +/- 1 W in six of seven patients. Using the large-tip electrode, an impedance rise occurred in five of 10 patients, but at 25 +/- 10 W and after 21 +/- 9 seconds. Atrioventricular block occurred before the impedance rise in three of these five patients. Complete atrioventricular block persisted in 15 of 16 patients at a mean follow-up of 8.7 months. Atrioventricular conduction returned at 1 month in one group 2 patient and was successfully ablated by a second procedure. Three group 1 patients died 0.5-2 months after ablation, and a fourth patient underwent cardiac transplantation after 10 months. Pathological examination of the heart in two of these patients showed necrosis of the atrioventricular node and origin of the His bundle, without injury to the middle or distal His bundle. All 10 group 2 patients are alive and subjectively improved after ablation. CONCLUSIONS We conclude that catheter-delivered radiofrequency current effectively produces complete atrioventricular block (94%) without requiring general anesthesia or the risk of ventricular dysfunction or cardiac perforation. The large-tip electrode allows a threefold increase in delivered power and markedly decreases the number of pulses and time required to produce atrioventricular block.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Catheter Ablation of Atrioventricular Junction Using Radiofrequency Current in 17 Patients

Background. Two catheter electrode systems were compared for delivering radiofrequency current for ablation of the atrioventricular junction. Seventeen patients with drug-resistant supraventricular tachyarrhythmias were studied. Methods and Results. A 6F or 7F catheter with six or eight standard electrodes (1.25 mm wide, 2.5-mm spacing) was used in the first seven patients (group 1). A 7F quadr...

متن کامل

Ablation of the atrioventricular junction with radiofrequency energy using a new electrode catheter.

Percutaneous catheter ablation using radiofrequency energy can be used to interrupt atrioventricular (AV) conduction in patients with supraventricular tachycardia refractory to drugs. Results of radiofrequency ablation of the AV junction using a custom-designed catheter with a large, 3-mm-long distal electrode, 2-mm interelectrode spacing, and a shaft with increased torsional rigidity were comp...

متن کامل

NASPE 25TH ANNIVERSARY SERIES Catheter Ablation of Supraventricular Arrhythmias: State of the Art

The era of catheter ablation for the treatment of arrhythmias began in 1981, when Dr. Melvin Scheinman performed the first atrioventricular junction ablation using direct-current shocks in a patient with drug-refractory atrial fibrillation and an uncontrolled ventricular rate.1 Because of the barotrauma associated with intracardiac high-energy shocks, direct-current catheter ablation played onl...

متن کامل

Catheter ablation of supraventricular arrhythmias: state of the art.

The era of catheter ablation for the treatment of arrhythmias began in 1981 when Dr. Melvin Scheinman performed the first atrioventricular junction ablation using direct current shocks in a patient with drug refractory atrial fibrillation and an uncontrolled ventricular rate.1 Because of the barotrauma associated with intracardiac, high energy shocks, direct current catheter ablation played onl...

متن کامل

Is 8-mm more effective than 4-mm tip electrode catheter for ablation of typical atrial flutter?

BACKGROUND The prospective, randomized study comparing 4- with 8-mm tip electrodes for radiofrequency linear ablation of typical atrial flutter is not available. METHODS AND RESULTS A total of 104 consecutive patients with typical atrial flutter were randomly assigned to undergo radiofrequency linear ablation using a 4- (Group I, n=54) or 8-mm tip electrode (Group II, n=50) catheter (temperat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 83 5  شماره 

صفحات  -

تاریخ انتشار 1991