Standardization of CalyculinA induced PCC assay and its advantages over Okadaic acid PCC assay in Biodosimetry applications
نویسندگان
چکیده
OBJECTIVE In the present study an attempt was made to estimate coefficients of dose response curves for PCC aberrations induced by CalyculinA and Okadaic acid, using 60Co gamma radiation and 8 MeV pulsed electron beam for biodosimetry application. MATERIALS AND METHODS The modified method outlined by Puig et al. 2013 was used to conduct Calyculin A and Okadaic acid induced PCC assay in human blood lymphocytes.Chemical treatment was given for the last 1 h of a 48 h culture. The study was carried out in the dose range 2.5 to 20 Gy using 60Co gamma rays and 8 MeV pulsed electron beam. RESULTS AND CONCLUSIONS Results show a linear dose dependent increase with a slope of 0.047 ± 0.001 from Calycalin A PCC and 0.048 ± 0.002 form Okadaic acid PCC. The slope of the fragments curve was 0.327 ± 0.006 from Calyculin A and 0.328 ± 0.006 from Okadaic acid PCC. Further, dose calibration studies were carried out for 8 MeV electron using Calyculin A PCC assay and the obtained slope from ring yield was 0.054 ± 0.002 and 0.427 ± 0.009 from fragment yield.
منابع مشابه
Biological Dose Assessment by Chemical Induction of Premature Chromosome Condensation
Dose assessment of radiation victims is a key element in medical management of radiation accidents. At high radiation doses (> 6 Gy), dicentric assay lose its efficiency and premature chromosome condensation (PCC) assay was proposed to overcome the restrictions of dicentric assay. It was shown that PCC ring is more suitable and simpler than dicentric for biodosimetry in high radiation doses. In...
متن کاملInduction of premature chromosome condensation (PCC) by calyculin A for biodosimetry
Background: Premature chromosome condensation (PCC) is a method for interphase chromosome analysis in biodosimetry. This study was performed to verify the usefulness of PCC induced by calyculin A in human peripheral blood lymphocytes (pbl) for biological dosimetry and possible construction of dose-response curve. Materials and Methods: Peripheral blood was obtained from a healthy donor and expo...
متن کاملConstruction of Calibration Curve for Premature Chromosome Condensation Assay for Dose Assessment
Cytogenetic dosimetry plays an important role in the triage and medical management of affected people in radiological incidents/accidents. Cytogenetic biodosimetry uses different methods to estimate the absorbed dose in the exposed individuals, and each approach has its advantages and disadvantages. Premature chromosome condensation (PCC) assay presents several advantages that hopefully fulfill...
متن کاملTriage biodosimetry using centromeric/telomeric PNA probes and Giemsa staining to score dicentrics or excess fragments in non-stimulated lymphocyte prematurely condensed chromosomes.
The frequency of dicentric chromosomes in human peripheral blood lymphocytes at metaphase is considered as the "gold-standard" method for biological dosimetry and, presently, it is the most widely used for dose assessment. Yet, it needs lymphocyte stimulation and a 2-day culture, failing the requirement of rapid dose estimation, which is a high priority in radiation emergency medicine and triag...
متن کاملInduction of Premature Chromosome Condensation (PCC) by Calyculin A for biodosimetry
B iological dosimetry of ionizing radiation is generally performed by scoring dicentrics and/or translocations in chromosome from peripheral blood lymphocytes (pbl) at the first mitosis following in vitro growth stimulation. It is well known that after irradiation, in this procedure mitotic index is low in some individuals, so the scored mitoses might not be representative of the exposed cell p...
متن کامل