Voltammetric determination of vitamins in a pharmaceutical formulation.

نویسندگان

  • I Siddiqui
  • K S Pitre
چکیده

Direct current polarography and differential pulse polarographic methods have been developed for the qualitative as well as quantitative analysis of vitamin B1, B2 and B6. Thiamin (vitamin B1) produced a well-defined wave in 0.1 M KCl at pH 5.2 with E(1/2)=-1.2 V and E(p)=-1.22 V versus saturated calomal electrode (SCE). Riboflavin (vitamin B2) gave two distinct waves in Britton Robinson buffer at pH 1.8 with E(1/2) values=-0.13 and -0.34 V versus SCE and at pH 6.5 with E(1/2)=-1.10 V and E(p)=-1.2 V versus SCE. Pyridoxin (vitamin B6) produced a well-defined wave in Britton Robinson buffer at pH 6.5 with E(1/2)=-1.7 V and E(p)=-1.68 V versus SCE. All the three vitamins under study are reversibly reduced at the electrode surface. The number of electrons involved in the electrode process for vitamin B1 and B6 is one in each case where as for the two waves of B2 it is one and two, respectively. This has been confirmed by the measurement of E(3/4)-E(1/4) values and also from the log plot slopes for the reduction waves. The wave height of polarogram was found to be proportional to the vitamin concentration. The developed methods have been standardised for the determination of these compounds in pharmaceutical formulation. The concentration of vitamin B1, B2 and B6 are found to be 9.96, 9.92 and 3.01 mg, respectively in 240 mg of capsule powder of a standard company (name has not been disclosed due to secrecy purpose). The results have been found to be in excellent agreement to that claimed by the manufacturer. The observed data has been subjected to statistical analysis, which revealed high reliability and precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum

In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Cal...

متن کامل

Voltammetric quantitation of nitazoxanide by glassy carbon electrode

The present study reports voltammetric reduction of nitazoxanide in Britton-Robinson (B-R) buffer by cyclic and square-wave voltammetry at glassy carbon electrode. A versatile fully validated voltammetric method for quantitative determination of nitazoxanide in pharmaceutical formulation has been proposed. A squrewave peak current was linear over the nitazoxanide concentration in the range of 2...

متن کامل

Voltammetric determination of glutathione in pharmaceutical and biological samples using multiwall carbon nanotubes paste electrode in the presence of rutin as a mediator

A new sensitive, selective and nonexpensive electrochemical sensor was developed for electrocatalyticdetermination of glutathione (GSH)in pharmaceutical and biological samples. GSH is a tripeptide thiol present in all eukaryotic and probiotic cells. A voltammetric studyof GSH has been carried out at the surface of carbon paste electrode modified with multiwall carbon nanotubes(MWCNTPE) in the p...

متن کامل

Simultaneous Voltammetric Determination of Nitazoxanide and Ofloxacin in Pharmaceutical Formulation

A simple, sensitive and highly selective electrochemical method was developed for the simultaneous determination of nitazoxanide and ofloxacin in aqueous media (Britton-Robinson buffer, pH-8.36) on a hanging mercury drop electrode (HMDE) using differential pulse polarography (DPP). Using DPP a separation of about 936 mV between the peak oxidation potentials of nitazoxanide and ofloxacin present...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 26 5-6  شماره 

صفحات  -

تاریخ انتشار 2001