The impact of the addition of iodoform on the physicochemical properties of an epoxy-based endodontic sealer
نویسندگان
چکیده
UNLABELLED Due to the low radiopacity of Sealer 26, iodoform is frequently empirically added to this sealer. Thus, the interference of this procedure with the physicochemical properties of Sealer 26 must be evaluated. OBJECTIVE This study evaluated the influence of the addition of iodoform on setting time, flow, solubility, pH, and calcium release of an epoxy-based sealer. MATERIAL AND METHODS The control group was pure Sealer 26, and the experimental groups were Sealer 26 added with 1.1 g, 0.55 g or 0.275 g of iodoform. Setting time evaluation was performed in accordance with the ASTM C266-03 speciflcation. The analysis of flow and solubility was in accordance with the ISO 6876-2001 speciflcation. For the evaluation of pH and calcium ion release, polyethylene tubes were filled with the materials and immersed in flasks with 10 ml of deionized water. After 24 h, 7, 14, 21, 28, and 45 days pH was measured. In 45 days, the calcium released was evaluated with an atomic absorption spectrophotometer. RESULTS The addition of iodoform increased setting time in comparison with pure sealer (P<0.05). As for flow, solubility, and calcium release, the mixtures presented results similar to pure sealer (p>0.05). In the 24 h period, the mixture with 1.1 g and 0.55 g of iodoform showed lower pH than pure sealer and than sealer added with 0.275 g of iodoform (P<0.05). CONCLUSIONS The iodoform added to Sealer 26 interferes with its setting time and solubility properties. Further studies are needed to address the clinical signiflcance of this interference.
منابع مشابه
The antibacterial activity of an epoxy resin-based dental sealer containing bioactive glass, hydroxyapatite, and fluorohydroxyapatite nanoparticles against Enterococcus Faecalis and Streptococcus mitis
Objective(s): The present study aimed to investigate the antibacterial properties of a conventional epoxy-based dental sealer modified with synthesized bioactive glass (BG), hydroxyapatite (HA), and fluorine-substituted hydroxyapatite (FHA) nano-fillers. Materials and Methods: The synthesized nano-fillers were incorporated into the conventional epoxy-based dental seaer at the concentratio...
متن کاملThe Effect of Adding Different Antibiotics on the Resistance against Bacterial Leakage of AH 26 Sealer
Aim: Most endodontic sealers show antimicrobial activity before setting, but most of them also lose this ability after setting. Addition of an antibiotic may affect the properties of sealers such as sealing ability, setting time, and so on. The aim of this study was to assess whether the addition of antibiotics (amoxicillin, doxycycline, and clindamycin) improves the sealing ability of AH 26 se...
متن کاملApplications of nanotechnology in endodontic: A Review
Owing to its favorable impacts on the properties of materials, nanotechnology is rapidly growing. Adding nano particles to a material can significantly affect its mechanical and physical properties. In recent years, nanotechnology has been applied in the field of medical sciences in order to enhance the quality of treatment procedures. This technology can be used in various aspects of dentistry...
متن کاملAn investigation on the adhesion of two endodontic sealers AH 26, Dorifill) to dentin (
An investigation on the adhesion of two endodontic sealers AH 26, Dorifill) to dentin ( * - Dr. S. Khedmat** Dr. M. Khorramdoost*- Assistant professor of Endodontics Dept. Faculty of Dentistry Tehran University of Medical Sciences. ** - Dentist. Background and aim: Tensile bond strength of endodontic sealers to dentin is an indicative of sealer's adhesion to dentin. Due to the fact that Gutta...
متن کاملPhysicochemical Properties of Epoxy Resin-Based and Bioceramic-Based Root Canal Sealers
Three bioceramic sealers (EndoSequence BC sealer, EndoSeal MTA, and MTA Fillapex) and three epoxy resin-based sealers (AH-Plus, AD Seal, and Radic-Sealer) were tested to evaluate the physicochemical properties: flow, final setting time, radiopacity, dimensional stability, and pH change. The one-way ANOVA and Tukey's post hoc test were used to analyze the data (P = 0.05). The MTA Fillapex sealer...
متن کامل