Characterization and Correction of Physiological Instabilities in 3D FMRI

نویسندگان

  • R. H. Tijssen
  • S. M. Smith
  • P. Jezzard
  • R. Frost
  • M. Jenkinson
  • K. L. Miller
چکیده

3D readouts generally have the advantage that they 1) allow imaging at a high isotropic resolution and 2) are inherently multi-shot sequences with short readout segments thereby reducing distortion artifacts. These advantages make sequences such as steady-state free-precession (SSFP) and spoiled gradient echo (SPGR) an attractive option for high resolution FMRI in areas such as the brainstem. Experiments have shown however that these sequences are prone to temporal instabilities in inferior areas of the brain (Fig. 1). In this work we present a characterisation of these instabilities by simulations and report preliminary results of a GRAPPA-based correction method that utilizes the additional information of the coil geometry to allow retrospective gating of 3D FMRI data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Physiological noise on Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field

Introduction: Functional MRI methods have been used to study sensorimotor processing in the brain and the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as signifi...

متن کامل

Effect of Physiological Noise on Thoraco-lumbar Spinal Cord FMRI in 3T Magnetic Field

Introduction: Functional MRI methods have been used to study sensorimotor processing in the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from the physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as significant sources of noise, especi...

متن کامل

Influence of physiological noise on accelerated 2D and 3D resting state functional MRI data at 7 T.

PURPOSE Physiological noise often dominates the blood-oxygen level-dependent (BOLD) signal fluctuations in high-field functional MRI (fMRI) data. Therefore, to optimize fMRI protocols, it becomes crucial to investigate how physiological signal fluctuations impact various acquisition and reconstruction schemes at different acquisition speeds. In particular, further differences can arise between ...

متن کامل

Real-time cardiac synchronization with fixed volume frame rate for reducing physiological instabilities in 3D FMRI

Although 2D echo-planar imaging (EPI) remains the dominant method for functional MRI (FMRI), 3D readouts are receiving more interest as these sequences have favorable signal-to-noise ratio (SNR) and enable imaging at a high isotropic resolution. Spoiled gradient-echo (SPGR) and balanced steady-state free-precession (bSSFP) are rapid sequences that are typically acquired with highly segmented 3D...

متن کامل

Sources of signal fluctuations in fMRI at 7 Tesla

The development of high-field magnetic resonance imaging (MRI) systems has allowed for critical improvements in image signal-to-noise ratio (SNR), potentially leading to higher sensitivity and spatial resolution for functional MRI (fMRI) techniques. However, recent studies have shown that these potential advantages become significantly compromised by increased signal fluctuations arising from c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009