The relationship between the bone characters obtained by CBCT and primary stability of the implants

نویسندگان

  • Masahiro Wada
  • Yasutane Tsuiki
  • Tohru Suganami
  • Kazunori Ikebe
  • Motofumi Sogo
  • Ikuhisa Okuno
  • Yoshinobu Maeda
چکیده

BACKGROUND The aim of this study is to investigate the correlation between the thickness of the cortical bone or the voxel values that are obtained by cone beam CT (CBCT) and the insertion torque values (ITVs) or the implant stability quotient (ISQ) values. METHODS A pig's ilium was used as the implant placement site. The implants used in this study were two kinds of diameters (3.8 mm, 5.0 mm) and two kinds of lengths (7.0 mm, 12.0 mm) having a general threadlike shape with a mechanically polished surface. To measure the bone density and the cortical thickness around the implants accurately, the CBCT scanning was performed immediately just after the formation of the implant cavity. The initial stabilities were evaluated by the ITVs and the ISQ values. The bone density and cortical thickness around the implants were measured by an implant simulation software (Landmarker ver. 5.0 with special specifications for this study). The relationships of the thickness of the cortical bone and the voxel values with the ITVs and the ISQ values were analyzed using Pearson's correlation coefficient. To evaluate the influence on the ITVs and the ISQ values among multiple factors, multiple regression analysis was performed. P < 0.05 was considered statistically significant. RESULTS A significant positive correlation was found between the thickness of the cortical bone and the ITVs or the ISQ values in all kinds of implants. In addition, a significant positive correlation was also found between the voxel values and the ITVs. From the multiple regression analysis, the thickness of the cortical bone and the voxel values had a positive influence on the ITVs and the ISQ values. In addition, the length of the implant had a positive influence on the ISQ values at the 3.8-mm-diameter implant. CONCLUSIONS In this limited study, there were correlations between the thickness of the cortical bone or the voxel values obtained from the CBCT scanning and the implant stabilities. Besides, it was confirmed that the thickness of the cortical bone, the voxel value, and the implant length had positive correlations with the ITVs and the ISQ values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی رابطه بین دانسیته استخوانی حاصل ازCone-Beam Computed Tomography با میزان ثبات اولیه ایمپلنت دندانی

Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...

متن کامل

Correlation between bone quality evaluated by cone-beam computerized tomography and implant primary stability.

PURPOSE To examine the relationship between bone quality, as evaluated by cone-beam computerized tomography (CBCT), and implant primary stability, as measured by resonance frequency analysis (RFA). MATERIALS AND METHODS A preliminary clinical study was conducted in which implant placements were scheduled for 20 patients. The CT scan was obtained after initial drilling, and implant stability w...

متن کامل

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis

Immediately loaded Xive and Nisastan implants the effect of macro-design on distribution of strain in surrounding bone: A finite element analysis Dr. A. Fazel * - Dr. SH. A. Alai ** - Dr. M. Rismanchian *** *Associate Professor of Prosthodontics Dept., Faculty of Dentistry and Dental Research Center, Tehran University / Medical Sciences. **Assistant Professor of Prosthodontics Dept., Faculty of...

متن کامل

مقایسه شاخص‌های سلامتی لثه در افراد دریافت کننده ایمپلنت‌های دندانی سیگاری و غیرسیگاری

  Background : Although factors such as implant length, location, and diameter as well as bone quality have been associated with excessive failure rates, smoking is suggested as a stronger predisposing factor for higher failure rates. Thus, knowing the relationship between bone loss around the dental implants, maintenance of the implants and smoking could be a principle step towards solving the...

متن کامل

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2015