A thermistor leaf thermometer.

نویسندگان

  • E T Linacre
  • W J Harris
چکیده

An instrument is described which allows measurements of leaf temperature within about 0.3 C. It consists of a special thermistor probe, a small circuit box, and a standard ammeter. The circuit box can easily be fixed to the meter and contains a battery, which passes 0.3 milliampere through the thermistor, and also contains an integrated circuit amplifier, so that the meter reads 20 C full scale deflection, with ranges adjustable in 10 C steps. Calibration experiments show the superiority of the thermistor leaf thermometer to a thermocouple pressed onto a rubber surface with a resilience resembling that of a leaf.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A digitally linearized thermistor thermometer referenced to IPTS-68.

We describe a digitally linearized thermistor thermometer that is accurate to +/- 0.01 degrees C from 0 to 60 degrees C at a wattage of 50 microW and a sampling time of 1 s. It is traceable to the International Practical Temperature Scale of 1968 (IPTS-68). Analog and digital outputs are provided, the latter as ASCII RS-232C. The thermistor is a 10-cm long immersible probe, 1.5 mm in diameter. ...

متن کامل

A low-noise thermistor bridge for use in calorimetry.

A precision thermistor bridge and thermistor is described for use ina thermaltitration calorimeteror a high-speed stoppedor continuous-flow calorimeter of the Roughton type. These are compared and evaluated with regard to several other types of detectors, including the platinum resistance thermometer, thermocouple, transistor thermometer, and capacitance thermometers. At this time the best dete...

متن کامل

An evaluation of infra-red tympanic thermometry for thermal physiology research.

This study forms part of a research programme to investigate the relationships between the rise in core temperature and the environmental temperature in soldiers exercising at a constant rate. The measurement of core temperature is a fundamental requirement for this research. The aim of this study was to evaluate the use of an infra-red tympanic thermometer (IVAC Corecheck) for use in thermal p...

متن کامل

A melting-point-of gallium apparatus for thermometer calibration.

We have investigated the equilibrium melting point of gallium as a temperature fixed-point at which to calibrate small thermistor thermometers, such as those used to measure temperature in enzyme reaction analysis and other temperature-dependent biological assays. We have determined that the melting temperature of "6N" (99.999% pure) gallium is 29.770 +/- 0.002 degrees C, and that the constant-...

متن کامل

Accuracy of temperature measurement in the cardiopulmonary bypass circuit.

Oxygenator arterial outlet blood temperature is routinely measured in the cardiopulmonary bypass (CPB) circuit as a surrogate for the temperature of the arterial blood delivered to sensitive organs such as the brain. The aim of this study was to evaluate the accuracy of the temperature thermistors used in the Terumo Capiox SX25 oxygenator and to compare the temperature measured at the outlet of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Plant physiology

دوره 46 2  شماره 

صفحات  -

تاریخ انتشار 1970