Does Restrictive Fluid Strategy during Robotic Pelvic Surgeries Obtund Intraoperative Rise in Intraocular Pressure?

نویسندگان

  • Pulak Tosh
  • Saritha Valsala Krishnankutty
  • Sunil Rajan
  • Hema Muraleedharan Nair
  • Nitu Puthanveettil
  • Lakshmi Kumar
چکیده

Background Robotic pelvic surgeries require steep Trendelenburg position which may result in rise in intraocular pressure (IOP). Aim The aim of this study was to compare the changes that occur in IOP during robotic pelvic surgeries in steep Trendelenburg position with a restrictive intravenous fluid administration. Settings and Design This prospective observational study was conducted in a tertiary care institution. Subjects and Methods Twenty consenting patients scheduled for pelvic robotic gynecological surgeries were enrolled. All patients received general anesthesia following a standardized protocol. IOP was measured before induction of anesthesia, immediately after induction and intubation, at the end of surgery immediately after making the patient supine and immediately after extubation. Ringer's lactate was administered intravenously at a rate of 4 mL/kg/h targeting a mean arterial pressure of >65 mmHg and urine output of >0.5 mL/kg/h. Statistical Analysis Used Paired t-test was used in this study. Results There was a fall in IOP soon after induction from baseline which was not significant. Immediately, following intubation, there was a significant rise in IOP. At the end of surgery, though IOP remained high, it was not statistically significant. However, following extubation, IOP rose further and the difference from the baseline became statistically significant. Although there was a moderate increase in peak airway pressure and highest EtCO2 levels during Trendelenburg from baseline values, the differences were statistically insignificant. Conclusion During robotic pelvic surgeries, adopting a restrictive intravenous fluid strategy with the maintenance of normal end-tidal carbon dioxide levels could abate effects of steep Trendelenburg position on IOP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting

Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP), body weights, as well as systolic and diastolic blood pressures (SBP, DBP) of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m...

متن کامل

Ciliary Body Tuberculosis Presenting with Attacks of Acute Intraocular Pressure Rise

Purpose: To report a rare presentation of ophthalmic tuberculosis. Case Report: A 19-year-old man was referred to the glaucoma clinic due to multiple attacks of increased intraocular pressure (IOP) in his right eye. IOP of the right eye was 50 mmHg, and glaucomatous damage of the optic nerve was present. In gonioscopy, an oval-black lesion was present in the ciliary body band on the temporal si...

متن کامل

Cataract Surgery with a New Fluidics Control Phacoemulsification System in Nanophthalmic Eyes

PURPOSE To report visual outcomes and complications after cataract surgery in nanophthalmic eyes with a phacoemulsification system using the active fluidics control strategy. METHODS This is a retrospective case series. All eyes with an axial length of less than 20 mm that underwent cataract surgery or refractive lens exchange using the Centurion Vision System (Alcon Laboratories Inc.) in Hon...

متن کامل

Intraoperative fluid management in open gastrointestinal surgery: goal-directed versus restrictive

OBJECTIVE The optimal strategy for fluid management during gastrointestinal surgery remains unclear. Minimizing the variation in arterial pulse pressure, which is induced by mechanical ventilation, is a potential strategy to improve postoperative outcomes. We tested this hypothesis in a prospective, randomized study with lactated Ringer's solution and 6% hydroxyethyl starch solution. METHOD A...

متن کامل

مقایسه‌ی تاثیر قطره‌ی میتومایسین Cحین و پس از عمل جراحی در عود، حدت بینایی و فشار داخل چشمی در جراحی ناخنک

Background and Objective: Pterygium is a common ocular surface disorder. A number of surgical procedures are used to remove it. The purpose of this study was to compare recurrent, visual acuity and intraocular pressure after pterygium surgery using mitomycin C during and after surgery. Materials and Methods: In this interventional study, 119 patients with indications for pterygium surgery were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2018