Use of the Bonfils Intubation Fiberscope in Patients with Limited Mouth Opening
نویسندگان
چکیده
Airway management of patients with very limited mouth opening remains a challenge for the anaesthetist. We describe the use of the Bonfils Intubation Fiberscope for awake intubation in two patients with a very limited mouth opening. In the first case, a 60-year-old 80 kg female, scheduled for a right modified radical mastectomy for infiltrating ductal carcinoma (15 mm mouth opening, a short thick neck, limited neck extension, and a Mallampati class 4 airway), the Bonfils was advanced via the retromolar technique. In the second patient, a 34-year-old male, scheduled for a surgical tracheotomy for right tonsillar cancer, due to a neoplastic infiltration of the right temporomandibular joint (7 mm mouth opening and limited neck movement), the Bonfils was advanced using the midline approach. The Bonfils is a reusable, rigid, straight fiberoptic device with a curved tip, is 5 mm in diameter, and has several advantages: it is quick and easy to use, more cost effective than a flexible fiberscope, and is safe in expert hands, thanks to its smaller diameter. Our conclusion is that awake BIF intubation is a reliable, atraumatic, and well-tolerated procedure to secure a safe airway in patients with a limited mouth opening.
منابع مشابه
Reduced hemodynamic responses to tracheal intubation by the Bonfils retromolar fiberscope: a randomized controlled study.
The Bonfils retromolar intubation fiberscope is a rigid endoscope designed to enable glottic visualization and facilitate intubation under endoscopic vision. Theoretically, avoiding direct-vision laryngoscopy and thus could produce less stimulation during intubation than the conventional direct laryngoscopic procedure. This prospective randomized study was designed to compare the effect of trac...
متن کاملImproving rigid fiberoptic intubation: a comparison of the Bonfils Intubating Fiberscope™ with a novel modification
BACKGROUND The Bonfils intubating fiberscope has a limited upward tip angle of 40 degrees and requires retromolar entry into the hypopharynx. These factors may make its use less desirable when managing the difficult airway because most anesthesia providers are well versed in midline oral intubation rather than the lateral retromolar approach. The Center for Advanced Technology and Telemedicine ...
متن کاملDifficult airway management with bonfils fiberscope in case of emergency: acute abdomen with ileus.
This clinical report describes an emergency case of a 49-year-old man, ASA E III status, with clinical symptoms of acute abdomen and ileus, who was scheduled for urgent surgery. Predictors of difficult intubation (Mallampati test Class III, short thyro-mental (< 6 cm) and sterno-mental distance (<10 cm) with limited mouth opening (inter-incisor gap < 3 cm) were associated with significant comor...
متن کاملComparison of the Airtraq to the Bonfils Fibroscope for Endotracheal Intubation in a Simulated Difficult Airway
Background: Difficult intubation, represent a challenge to anesthetist especially that many cases are encountered after induction of anesthesia. The Airtraq and the Bonfils fibroscopes are new devices designed to facilitate intubation under normal and difficult circumstances. In the present study, the efficacy and the intubation success rate of the Airtraq to the Bonfils fiberscope were evaluat...
متن کاملAwake endotracheal intubation in patients with severely restricted mouth opening- alternative devices to fiberscope: series of cases and literature review
Awake Fiberoptic Intubation (AFI) is a standard method of airway management in the case of anticipated difficult intubation. It is usually performed with the use of flexible fiberscopes. In this report we have described two methods in which alternative devices to the fiberscope were utilized for awake intubation in patients with severely restricted mouth opening scheduled for craniomaxillofacia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2012 شماره
صفحات -
تاریخ انتشار 2012