Methodology for airflow rate measurements in a naturally ventilated mock-up animal building with side and ridge vents
نویسندگان
چکیده
11 Currently there exists no generally accepted reference technique to measure the ventilation rate 12 through naturally ventilated (NV) vents. This has an impact on the reliability of airflow rate control 13 techniques and emission rate measurements in NV animal houses. As an attempt to address this issue a 14 NV test facility was built to develop new airflow rate measurement techniques for both side wall and 15 ridge vents. Three set-ups were used that differed in vent configuration, i.e. one cross ventilated set-up 16 and two ridge ventilated set-ups with different vent sizes. 17 The airflow through the side vents was measured with a technique based on an automatic traverse 18 movement of a 3D ultrasonic anemometer. In the ridge, 7 static 2D ultrasonic anemometers were 19 installed. The methods were validated by applying the air mass conservation principle, i.e. the inflow 20 rates must equal the outflow rates. 21 The calculated inand outflow rates agreed within (5 ± 8)%, (8 ± 5)% and (-9 ± 7)% for the three 22 different set-ups respectively, over a large range of wind incidence angles. It was found that the side 23 vent configuration was of large importance for the distribution of the airflow rates through the vents. 24 The ridge proved to be a constant outlet, whilst side vents could change from outlet to inlet depending 25 on the wind incidence angle. The range of wind incidence angles in which this transition occurred 26 could be clearly visualised. 27 M AN US CR IP T AC CE PT ED ACCEPTED MANUSCRIPT
منابع مشابه
Assessing airflow rates of a naturally ventilated test facility using a fast and simple algorithm supported by local air velocity measurements
The high spatial and temporal variations of airflow patterns in ventilation openings of naturally ventilated animal houses make it difficult to accurately measure the airflow rate. This paper focusses on the development of a fast assessment technique for the airflow rate of a naturally ventilated test facility through the combination of a linear algorithm and local air velocity measurements. Th...
متن کاملAir Quality and Emission Measurement Methodology
Reliable measurements of air quality and emissions at large livestock buildings with inherently large spatial and temporal variations of pollutant concentrations are relatively difficult and expensive. Appropriate methodologies for such measurements are not readily apparent and techniques and strategies vary widely. Several important technical issues need to be addressed by an air pollutant emi...
متن کاملStudy of Dioxide Carbon Concentration and Indoor Air Quality in Some Buildings in the Equatorial Region of Cameroon (Yaounde)
Background and purpose: Elevated CO2 rate in a building affect the health of occupant. This document presents results of an experimental analysis conducted in 50 offices located in 12 buildings with different layer in Cameroon (Yaounde). This study took place in 2012, during the dry and the rainy seasons. The main goal is to show the influence of the building structure, the ventilation and the ...
متن کاملThe Impact of Traffic-related Pollutant on Indoor Air Quality in Buildings near Main Roads
Traffic–related pollutant has been recognized as an air pollution hot spot due to its large emission rate and great health impacts for the exposed population. In the present investigation, a computational fluid dynamics technique is used to evaluate the effect of traffic pollutions on indoor air quality of a naturally ventilated building. The transport of street-level nonreactive pollutants emi...
متن کاملAssessing effects of different opening combinations on airflow pattern and air exchange rate of a naturally ventilated dairy building –A CFD approach
Ventilation airflow in buildings is paramount important for creating comfortable environment with acceptable indoor air quality by regulating indoor air parameters, such as air temperature, relative humidity, air speed, and concentrations of chemical species in the air. Airflow inside naturally ventilated dairy (NVD) building is highly variable because of the direct effect of outside weather an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -