Ex vivo evaluation of a bipolar application concept for radiofrequency ablation.

نویسندگان

  • Urte Zurbuchen
  • Bernd Frericks
  • André Roggan
  • Kai Lehmann
  • Daniela Bössenroth
  • Heinz-J Buhr
  • Jörg-Peter Ritz
چکیده

BACKGROUND Bipolar radiofrequency ablation (RFA) can avoid complications such as thermal tissue damage, a possible consequence of monopolar RFA. However, basic studies about the dosage/effect relationship of bipolar systems are missing. This is systematic research on ex vivo beef livers to find which capacity parameters produce high energy in the tissue and achieve large lesion volumes. MATERIALS AND METHODS The active lengths 20, 30 and 40 mm of a bipolar, internally cooled applicator were studied. The tissue was fresh ex vivo beef liver. Five measurements each for each active applicator with a power between 10 and 50 W were conducted. RESULTS The best power for the 20 mm applicator was 15 W, since the highest achieved volume was 5,599+/-1,760 mm(3) and the highest amount of energy introduced to the tissue was 15+/-3 kJ. The best power for the 30 mm applicator was 20 W (volume 14,538+/-1,220 mm(3), energy 24+/-1 kJ). For the 40 mm applicator, the best power was 20 W, (volume 20,562+/-896 mm(3), energy 24+/-0 kJ). CONCLUSION The results of this study help clinicians determine which active length is required for the applicator and which presetting should be selected to achieve a defined coagulation volume size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bipolar radiofrequency ablation of the kidney: comparison with monopolar radiofrequency ablation.

PURPOSE We report initial ex vivo and in vivo studies using bipolar radiofrequency (RF) ablation of porcine kidneys. An internal ground electrode is positioned in the kidney opposite the RF electrode, resulting in ablation of all the intervening renal tissue. MATERIALS AND METHODS Ex vivo preparations of 10 porcine kidneys were perfused continuously with Ringer's solution and treated with eit...

متن کامل

An Investigation of Brightness Changes in Ultrasound Images due to Temperature Variations in Liver Tissue during Radiofrequency Ablation

Introduction: one of the minimally invasive methods of treatmenting liver malignancies is Radiofrequency Ablation (RFA) which can be applied to primary or secondary tumors. Nevertheless, the disease recurrence is probable after RFA application partially due to the inadequate capability of temperature monitoring of the target tissue and visualizing the thermal damage. The goal of this work was t...

متن کامل

Fluid-modulated bipolar radiofrequency ablation: an ex-vivo evaluation study.

BACKGROUND The effect of radiofrequency ablation (RFA) can be modulated by fluid injection. PURPOSE To evaluate the potential of different fluids to modulate the effect of bipolar RFA in an ex-vivo liver model. MATERIAL AND METHODS A bipolar RFA system with an internally cooled needle-shaped applicator (20-mm active tip) was used to induce coagulation lesions in ex-vivo porcine liver. Prior...

متن کامل

Morphological Changes Induced by Bipolar Radiofrequency Ablation in Thyroid Nodules – a Preclinical Ex Vivo Investigation

I ntroduction: Recently, radiofrequency ablation (RFA) has been increasingly used for the treatment of thyroid nodules. However, immediate morphological changes associated with bipolar devices are poorly shown. Aims: To present the results of analysis of gross and microscopic alterations in human thyroid tissue induced by RFA delivered through the application of the original patented device. Ma...

متن کامل

Bipolar and multipolar radio frequency ablation with resistance controlled power output: standardized ex vivo kidney tissue evaluation.

PURPOSE We investigated a newly developed bipolar and multipolar RF ablation system with an internally cooled electrode and resistance controlled power output in a standardized model of perfused ex vivo kidney tissue. MATERIALS AND METHODS RF energy was applied at different power levels (20, 30 and 60 W) for 1, 3, 5 and 9 minutes. Each treatment parameter was repeated 5 times. For the 20/30 W...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anticancer research

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 2009