Evaluation of a novel nanocrystalline hydroxyapatite paste Ostim® in comparison to Alpha-BSM® - more bone ingrowth inside the implanted material with Ostim® compared to Alpha BSM®

نویسندگان

  • Franz-Xaver Huber
  • Nicholas McArthur
  • Lydia Heimann
  • Elvira Dingeldein
  • Héloïse Cavey
  • Xavier Palazzi
  • Gaëlle Clermont
  • Jean-Pierre Boutrand
چکیده

BACKGROUND The purpose of this study was to evaluate the performance a newly developed nanocrystalline hydroxyapatite, OSTIM following functional implantation in femoral sites in thirty-eight sheep for 1, 2 or 3 months. Ostim 35 was compared to an established calcium phosphate, Alpha BSM. METHODS Biomechanical testing, micro-CT analysis, histological and histomorphological analyses were conducted to compare the treatments including evaluation of bone regeneration level, material degradation, implant biomechanical characteristics. RESULTS The micro-computed tomography (microCT) analysis and macroscopic observations showed that Ostim seemed to diffuse easily particularly when the defects were created in a cancellous bone area. Alpha BSM remained in the defect.The performance of Ostim was good in terms of mechanical properties that were similar to Alpha BSM and the histological analysis showed that the bone regeneration was better with Ostim than with Alpha BSM. The histomorphometric analysis confirmed the qualitative analysis and showed more bone ingrowth inside the implanted material with Ostim when compared to Alpha BSM at all time points. CONCLUSIONS The successful bone healing with osseous consolidation verifies the importance of the nanocrystalline hydroxyapatite in the treatment of metaphyseal osseous volume defects in the metaphyseal spongiosa.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a novel nanocrystalline hydroxyapatite paste and a solid hydroxyapatite ceramic for the treatment of critical size bone defects (CSD) in rabbits.

The purpose of our study was to test the effectiveness of Ostim nanocrystalline hydroxyapatite paste and Cerabone ceramic by treating a critical size bone defect (CSD) on the right foreleg of a white New Zealand rabbit. Evaluation was carried out by comparing four groups each with a different CSD filling: an only OSTIM bone filling, an only Cerabone filling, an OSTIM-Cerabone combination, and a...

متن کامل

First histological observations on the incorporation of a novel nanocrystalline hydroxyapatite paste OSTIM® in human cancellous bone

BACKGROUND A commercially available nanocrystalline hydroxyapatite paste Ostim has been reported in few recent studies to surpass other synthetic bone substitutes with respect to the observed clinical results. However, the integration of this implantable material has been histologically evaluated only in animal experimental models up to now. This study aimed to evaluate the tissue incorporation...

متن کامل

Corrigendum to “Comparative Study on the Efficacy of Anorganic Bovine Bone (Bio-Oss) and Nanocrystalline Hydroxyapatite (Ostim) in Maxillary Sinus Floor Augmentation”

Purpose. The aim of this study was to evaluate the efficacy of anorganic bovine bone (Bio-Oss) in comparison with nanocrystalline hydroxyapatite (Ostim) in sinus floor augmentation. Methods. Ten patients aged 40-80 were selected. All the patients needed sinus floor augmentation due to insufficient bone for simultaneous implant placement. The patients underwent panoramic radiography and cone bea...

متن کامل

A Novel Virtual Reality Technique (Cervigame®) Compared to Conventional Proprioceptive Training to Treat Neck Pain: A Randomized Controlled Trial

Background: Despite the potential benefits of virtual reality technology in physical rehabilitation, only a few studies have evaluated the efficacy of this type of treatment in patients with neck pain.Objective: The aim of this study was to compare the effects of virtual reality training (VRT) versus conventional proprioceptive training (CPT) in patients with neck pain.Methods: Forty four parti...

متن کامل

Evaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study

Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009