Robotic dexterity: evaluation of three-dimensional monitoring system and non-dominant hand maneuverability in robotic surgery

نویسندگان

  • Norihiko Ishikawa
  • Go Watanabe
  • Yasumitsu Hirano
  • Noriyuki Inaki
  • Kenji Kawachi
  • Makoto Oda
چکیده

There has been great progress in robotic surgical technology in recent years. The aim of this study was to objectively quantify robot-enhanced dexterity. To evaluate three-dimensional monitoring and non-dominant hand maneuverability using the da Vinci Surgical System, five surgeons were asked to thread the needle through all 11 holes on the model with handling robotic instrument. Three types of suturing were carried out. In task 1, sutures were placed using the dominant hand under 3D imaging; in task 2, suturing was performed using the dominant hand under 2D imaging; and in task 3, suturing was done with the non-dominant hand under 3D imaging. Each surgeon placed three sutures in completing each task. The time to successful completion, accuracy, and the opinion of the level of difficulty were recorded. All 45 tasks were completed. The time required to place each suture (mean ± SD) was as follows: 211.7 ± 50.5 s for task 1, 331.1 ± 121.2 s for task 2, and 237.1 ± 95.7 s for task 3. Task 1 took less time than task 2 (P = 0.02). There were no differences in the times between task 1 and task 3 (P = 0.19). Robotic suturing under 3D imaging is significantly faster than under 2D imaging, and robotic suturing using the non-dominant hand does not need significantly more time than with the non-dominant hand. Technology for robotic surgery could increase the manipulative abilities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robotic surgery: change in new surgery techniques

Medical science experts have reached scientific and technological improvements in recent ‎decades and have turned surgery into a routine treatment by controlling its complications. ‎Cumulative changes in surgery resulted in decreased pain and discomfort and controlled ‎complications. The developmental path and changes have resulted in endoscopic with minimal ‎invasive surgery (M...

متن کامل

Experimental Identification and Hybrid PID-Fuzzy Position Control of Continuum Robotic Arms

Continuum robotic arms that are inspired from nature, have many advantages compared to traditional robots, which motivate researchers in this field. Dynamic modeling and controlling these robots are challenging subjects due to complicated nonlinearities and considerable uncertainties existing in these structures. In this paper, first a dynamic three-dimensional model of the continuum robotic ar...

متن کامل

Grasp analysis of a four-fingered robotic hand based on Matlab simmechanics

The structure of the human hand is a complex design comprising of various bones, joints, tendons, and muscles functioning together in order to produce the desired motion. It becomes a challenging task to develop a robotic hand replicating the capabilities of the human hand. In this paper, the analysis of the four-fingered robotic hand is carried out where the tendon wires and a spring return me...

متن کامل

A scalarization-based method for multiple part-type scheduling of two-machine robotic systems with non-destructive testing technologies

This paper analyzes the performance of a robotic system with two machines in which machines are configured in a circular layout and produce non-identical parts repetitively. The non-destructive testing (NDT) is performed by a stationary robotic arm located in the center of the circle, or a cluster tool. The robotic arm integrates multiple tasks, mainly the NDT of the part and its transition bet...

متن کامل

Microsurgical robotic system for the deep surgical field: development of a prototype and feasibility studies in animal and cadaveric models.

OBJECT To enhance the surgeon's dexterity and maneuverability in the deep surgical field, the authors developed a master-slave microsurgical robotic system. This concept and the results of preliminary experiments are reported in this paper. METHODS The system has a master control unit, which conveys motion commands in six degrees of freedom (X, Y, and Z directions; rotation; tip flexion; and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -