Reproductive efficiency of a new modified boar semen extender for liquid storage

نویسندگان

  • C. Bresciani
  • G. Morini
  • F. Di Ianni
چکیده

In the present study the Authors developed a new modified boar semen extender for short-term liquid storage, based on the use of amikacin sulphate and fructose rather than gentamicin and glucose. The new extender (ME-S) was evaluated and compared in vitro to commercial ones (CRONOS, TRIXcell) and to a modified extender designated for long term storage (ME-L) for progressive motility. Progressive motility was not different (P40.05) among extenders until 120 h of storage, as differences among extenders became significant (Po0.05) at 144 and 166 h. Motility data across time were better for ME-S than TRIXcell (Po0.05). No differences were observed about the morphology and membrane integrity (ORT) among the new extender (ME-S) and the commercial ones. Following the results of the in vitro comparison, an artificial insemination field trial was performed for reproductive efficacy. In this trial ME-L was not used because it was not completely reliable yet. A total of 1011 sows were bred: 506 with ME-S and 505 with a commercial one (CRONOS). The pregnancy rate for ME-S was 93.68% (474 pregnant sows), as the commercial extender resulted in 452 pregnancies (89.5%). The statistical comparison was significant (Po0.05) and the number of live piglets born showed an increase of 52. & 2013 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Opportunities For Improving Reproductive Management And Efficiency Of The Swine Breeding Herd With Artificial Insemination

Current Status of AI Use The USA swine breeding herd has been reported to include 3.9 million sows. Approximately 60% of these sows were determined to have been mated by artificial insemination. Each sow received 6.5 doses of semen annually, for a total of 25 million doses utilized in a single year (1999, Boar Semen Conference). Most of the AI is performed with 3 billion sperm in 80 cc of a 5-d...

متن کامل

The use of comet assay to assess DNA integrity of boar spermatozoa following liquid preservation at 5 ̊C and 16 ̊C

The comet assay, under neutral conditions, allows the assessment of DNA integrity influenced by sperm ageing, which is manifested in DNA double-strand breaks. Here, we attempted to use a modified neutral comet assay test (single-cell gel electrophoresis), to our knowledge for the first time, to assess DNA integrity of boar spermatozoa during liquid storage for 96 h at 5 ̊C and 16 ̊C. In this come...

متن کامل

A retrospective study on effects of storage time of liquid boar semen on reproductive performance in Norwegian swine.

The objective of this retrospective field study was to determine the effects of storing, for up to 62 h, heterospermic and homospermic semen in the short-term extender Beltsville thawing solution (BTS), on reproductive performance in Norwegian swine of four different breed combinations. The study was based on fertility records after single or double inseminations with semen collected at an AI s...

متن کامل

Use of boar spermatozoa for artificial insemination. III. Fecundity of boar spermatozoa stored in Beltsville liquid and Kiev extenders for three days at 18 C.

A field trial was conducted on several hundred farms in The Netherlands to compare the fertilizing capacity of boar spermatozoa stored for 1, 2, or 3 d at 18 C in either Kiev or Beltsville liquid extender (BL-1). Two storage volumes (25 and 100 ml) were used. Twelve Dutch Landrace boars, all in routine commercial artificial insemination service, provided the semen in twice-a-week collections. O...

متن کامل

Effects of long-term liquid commercial semen extender and storage time on the membrane quality of boar semen

The objective of this study was to assess the sperm membrane integrity in extended boar semen during storage time using specific spectrum laboratory methods. Boar semen was diluted with the long-term liquid commercial extenders Androhep (A), Androstar (AS), Androstar plus (AS+), LD and M III and was stored up to 96 h. The sperm membrane integrity was evaluated by motility, viable spermatozoa, s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013