Blood nickel concentrations in patients with stainless-steel hip prostheses.
نویسندگان
چکیده
Nickel concentrations were analyzed by electrothermal atomic absorption spectrophotometry in serum and whole blood specimens from patients 9 to 15 years after unilateral (N = 11) or bilateral (N = 2) hip arthroplasty. The hip prostheses were of the "Charnley" or "TR-28" (metal-to-plastic) types, fabricated of stainless-steel (14 to 16 percent Ni) with polyethylene acetabular cups. In 12 of the 13 patients, nickel concentrations (+/- SD) averaged 0.30 +/- 0.25 microgram per L (range 0.05 to 0.85) in serum and 0.36 +/- 0.20 microgram per L (range 0.11 to 0.67) in whole blood; these values did not differ significantly from the corresponding nickel concentrations in specimens from 30 healthy controls (0.28 +/- 0.24 microgram per L, range less than 0.05 to 1.08, in serum; 0.34 +/- 0.28 microgram per L, range less than 0.05 to 1.05, in whole blood). The remaining patient, a 78-year-old man with bilateral hip arthroplasty, had nickel concentrations of 3.1 micrograms per L in serum and 2.3 micrograms per L in whole blood; renal insufficiency apparently contributed to hypernickelemia in this patient. The arthroplasty patients were asymptomatic with respect to their joint replacements; X-rays at the last follow-up examinations did not reveal bone resorption around the implants. This study shows that patients with stainless-steel hip prostheses of the metal-to-plastic types do not develop hypernickelemia in the apparent absence of corrosion, local complications, or systemic conditions, such as renal insufficiency.
منابع مشابه
Increased chromosome translocations and aneuploidy in peripheral blood lymphocytes of patients having revision arthroplasty of the hip.
The long-term biological effects of wear debris are unknown. We have investigated whether there is any evidence of cumulative mutagenic damage in peripheral blood lymphocytes of patients undergoing revision arthroplasty of predominantly metal-on-plastic total hip replacements compared with those at primary arthroplasty. There was a threefold increase in aneuploidy and a twofold increase in chro...
متن کاملMetallosis of the Resurfaced Hip
Metallosis of the hip is usually defined as aseptic fibrosis, local necrosis, or loosening of the prosthesis secondary to metallic corrosion and release of wear debris.8 It has also been defined as gray discoloration of the tissues of the joint, pain, an effusion, and elevated serum metal levels. Metallosis has been found with stainless steel, titanium, and cobalt chromium alloy femoral prosthe...
متن کاملAbsorption of Nickel, Chromium, and Iron by the Root Surface of Primary Molars Covered with Stainless Steel Crowns
Objective. The purpose of this study was to analyze the absorption of metal ions released from stainless steel crowns by root surface of primary molars. Study Design. Laboratory research: The study included 34 primary molars, exfoliated or extracted during routine dental treatment. 17 molars were covered with stainless-steel crowns for more than two years and compared to 17 intact primary molar...
متن کاملInfluence of processing parameters and sintering atmosphere on the mechanical properties and microstructure of porous 316L stainless steel for possible hard-tissue applications
The 316L stainless steel has been widely used in both artificial knee and hip joints in biomedical applications. The average lifetime of artificial hip joints is about 10 years due to aseptic loosening of the femoral stem attributed to polymeric wear debris; however, there is a steadily increasing demand from younger osteoarthritis patients aged between 15 and 40 years for a longer lasting join...
متن کاملA Monte Carlo study on electron and neutron contamination caused by the presence of hip prosthesis in photon mode of a 15 MV Siemens PRIMUS linac
Several investigators have pointed out that electron and neutron contamination from high-energy photon beams are clinically important. The aim of this study is to assess electron and neutron contamination production by various prostheses in a high-energy photon beam of a medical linac. A 15 MV Siemens PRIMUS linac was simulated by MCNPX Monte Carlo (MC) code and the results of percentage depth ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 15 6 شماره
صفحات -
تاریخ انتشار 1985