In vitro validation of the Affinity NT oxygenator arterial outlet temperatures.
نویسندگان
چکیده
During cardiopulmonary bypass, the rates of cooling and rewarming and the maximum temperatures attained are implicated in patient morbidity. Thus, accurate oxygenator arterial outlet temperature measurements are needed. The purpose of this study was to determine the accuracy of the arterial outlet temperature probe on the "Affinity NT" membrane oxygenator in measuring perfusate temperatures. An in vitro circuit was used. Crystalloid solution was recirculated through an Affinity NT membrane oxygenator and, to simulate the patient, a second oxygenator. Water was recirculated through the heat exchanger of the second oxygenator via a reservoir. A myocardial temperature probe was inserted in-line 4 cm distal to the Affinity NT oxygenator arterial outlet temperature probe and was considered to measure the actual temperature of the perfusate. Temperatures were simultaneously recorded from the in-line probe, arterial outlet probe, and reservoir every second. Twenty-seven trials were run using random combinations of three Affinity NT oxygenators and three in-line probes. Each trial entailed cooling an initially normothermic reservoir to 28 degrees C and then rewarming it to normothermia again. The arterial outlet temperature probe on the Affinity NT membrane oxygenator underestimated the perfusate temperatures during early rewarming (bias of 0.72 degrees C; precision of +/-1.15 degrees C) and late rewarming (bias of 0.52 degrees C; precision of +/-0.97 degrees C). An overestimation of the perfusate temperatures occurred during early cooling (bias of -0.57 degrees C; precision of +/-1.37 degrees C). Only during the late cooling phase was the arterial outlet temperature probe accurate (bias of -0.02 degrees C; precision of +/-0.3 degrees C). The perfusionist should be aware of the temperature probe monitoring characteristics of the oxygenator to safely perfuse the patient.
منابع مشابه
Air Transmission Comparison of the Affinity Fusion Oxygenator with an Integrated Arterial Filter to the Affinity NT Oxygenator with a Separate Arterial Filter.
Arterial filters used in the extracorporeal circuit (ECC) have been shown to minimize cerebral injury by capturing particulate matter and microbubbles. We clinically use the Affinity NT oxygenator with an Affinity arterial filter attached ("Affinity system"). The new Affinity Fusion oxygenator ("Fusion") incorporates integrated arterial filtering. Our aim was to determine if the Fusion oxygenat...
متن کاملOxygenator safety evaluation: a focus on connection grip strength and arterial temperature measurement accuracy.
This report describes the assessment of three specific safety-related specifications in the consideration of an alternate oxygenator; first the grip strength relationship between various oxygenator connectors and SMARxT tubing, second, the grip strength of various biopassive tubings and an isolated SMARxT connector, and finally, the accuracy of the arterial outlet temperature measurement. Grip ...
متن کاملAccuracy of temperature measurement in the cardiopulmonary bypass circuit.
Oxygenator arterial outlet blood temperature is routinely measured in the cardiopulmonary bypass (CPB) circuit as a surrogate for the temperature of the arterial blood delivered to sensitive organs such as the brain. The aim of this study was to evaluate the accuracy of the temperature thermistors used in the Terumo Capiox SX25 oxygenator and to compare the temperature measured at the outlet of...
متن کاملEffect of Normobaric versus Hypobaric Oxygenation on Gaseous Microemboli Removal in a Diffusion Membrane Oxygenator: An In Vitro Comparison.
Gaseous microemboli (GME) are an abnormal physiological occurrence during cardiopulmonary bypass and extracorporeal membrane oxygenation (ECMO). Several studies have correlated negative sequelae with exposure to increased amounts of GME. Hypobaric oxygenation is effective at eliminating GME in hollow-fiber microporous membrane oxygenators. However, hollow-fiber diffusion membrane oxygenators, w...
متن کاملWorking toward Best Practice: Microbubble Filtration and Patient Safety During Extracorporeal Circulation.
I have read with great interest the article from Potger et al. (1), and commend the authors for the contribution they make in this investigation. While congratulating them on their work, I also raise the following points to continue what I believe is much needed discussion on the very important topic of gas-bubble transmission during extracorporeal circulation (ECC). To build an appropriate con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 37 2 شماره
صفحات -
تاریخ انتشار 2005