Magnetic Retraction of Bowel by Intraluminal Injectable Cyanoacrylate-Based Magnetic Glue

نویسندگان

  • Zhigang Wang
  • Andrew Brown
  • Pascal André
  • Stuart I. Brown
  • Gordon J. Florence
  • Alfred Cuschieri
چکیده

Magnetic retraction offers advantages over physical retraction by graspers because of reduced tissue trauma. The objectives of this study are to investigate a novel method of magnetisation of bowel segments by intraluminal injection of magnetic glue and to demonstrate the feasibility of magnetic retraction of bowel with sufficient force during minimal access surgery. Following an initial materials characterisation study, selected microparticles of stainless steel (SS410- μ Ps) were mixed with chosen cyanoacrylate glue (Loctite 4014). During intraluminal injection of the magnetic glue using ex vivo porcine colonic segments, a magnetic probe placed at the injected site ensured that the SS410-μPs aggregated during glue polymerisation to form an intraluminal mucosally adherent coagulum. The magnetised colonic segments were retracted by magnetic probes (5 and 10 mm) placed external to the bowel wall. A tensiometer was used to record the retraction force. With an injected volume of 2 mL in a particle concentration of 1 g/mL, this technique produced maximal magnetic retraction forces of 2.24 ± 0.23 N and 5.11 ± 0.34 N (n = 20), with use of 5 and 10 mm probes, respectively. The results indicate that the formation of an intraluminal coagulum based on SS410- μPs and Loctite 4014 produces sufficient magnetic retraction for bowel retraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Application of a New Cyanoacrylate Glue in Pediatric Surgery for Fistula Closure

Surgical glues have been used in pediatric surgery because of the fragility of tissue, and to prevent major surgeries. The present report describes our experience with using a new cya-noacrylate Glubran 2 (Viareggio, Italy) in the treatment of five cases of tracheoesophageal atresia with fistula (one fistula protection, three recurrent fistula, and one unstable patients), two cases of hypospadi...

متن کامل

Comparison of the use of silk sutures and cyanoacrylate tissue glue after periodontal flaps in patients with moderate periodontitis

Comparison of the use of silk sutures and cyanoacrylate tissue glue after periodontal flaps in patients with moderate periodontitis Dr. A. Mogharehabed* - Dr. SH. Mirmohammadi** *- Assistant Professor of Periodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Dentist. Background and Aim: The use of silk suturing materials and cyanoacrylate tissue glue are common ...

متن کامل

A single-surgeon randomized trial comparing sutures, N-butyl-2-cyanoacrylate and human fibrin glue for mesh fixation during primary inguinal hernia repair.

BACKGROUND We sought to determine the efficacy of sutures, human fibrin glue and N-butyl-2-cyanoacrylate for mesh fixation in patients undergoing the plug and mesh procedure for groin hernia. METHODS A total of 156 patients with 167 inguinal hernias (11 bilateral) underwent a plug and mesh procedure and were randomly assigned to received either sutures (n = 59 hernias), human fibrin glue (n =...

متن کامل

Comparison of silk sutures and 2–ethyl–cyanoacrylate on wound closure following surgical crown lengthening using apically positioned flap surgery

Comparison of silk sutures and 2–ethyl–cyanoacrylate on wound closure following surgical crown lengthening using apically positioned flap surgery Dr. A. Moghareh Abed* - Dr. M. E'tesampoor*** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Background and Aim: The use of cyanoacrylate tissue glue as an alternative to silk sutur...

متن کامل

Computed Tomography Enterography and Magnetic Resonance Enterography in the Diagnosis of Crohn's Disease

Imaging of the small bowel is complicated by its length and its overlapping loops. Recently, however, the development of crosssectional imaging techniques, such as computed tomography enterography (CTE) and magnetic resonance enterography (MRE) has shifted fundamental paradigms in the diagnosis and management of patients with suspected or known Crohn's disease (CD). CTE and MRE are noninvasive ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -