An evaluation study on the quietness of the ATS valve.
نویسنده
چکیده
BACKGROUND The closure sound of the ATS bileaflet mechanical valve is said to be quieter than that of the other mechanical valves. However, the reasons for this are still unknown. In this study, we investigated the reasons for the quietness of the ATS valve closure sound. PATIENTS AND METHODS The valve closure sound was evaluated in 70 patients and in another 70 patients in whom the SJM valve had been used for single valve replacement, based on frequency analysis of the closure sound, measurement of the opening angle of the valve, cardiac function, and patient interviews. RESULTS In the valve closure sound analysis, the mean peak frequency of the valve closure sound was 1.02 kHz for the ATS valve, and the mean pressure was 22.8+/-4.04 dB. The mean peak frequency of the closure sound of the SJM valve was1.02 kHz, with another intermittent peak at 3 to 9 kHz in the human audibility range. The mean sound pressure was 25.0+/-3.20 dB. The noise classification score was 2.07+/-1.95 points for the SJM valve, significantly higher as compared with that for the ATS valve which was 0.36+/-0.95 points. Multilateral examinations showed a significant difference in the mean opening angle between the ATS and the SJM valves: the angle was 76.6+/-4.67 degrees for the ATS valve and 82.3+/-2.05 degrees for the SJM valve. CONCLUSION In view of the lower sound pressure in the human audibility range and lower patient awareness of the valve closure sound, the ATS valve would appear to be a superior mechanical valve when compared to the SJM valve from the point of view of the quality of life of the patients. The significant difference in the opening angle in patients with the ATS valve between those who were aware of the valve closure sound and those who were not suggested a possible association between the opening angle and the patient awareness of the valve closure sound.
منابع مشابه
Performance Evaluation of Magnetorheological Damper Valve Configurations Using Finite Element Method
The main purpose of this paper is to study various configurations of a magnetorheological (MR) damper valve and to evaluate their performance indices typically dynamic range, valve ratio, inductive time constant and pressure drop. It is known that these performance indices (PI) of the damper depend upon the magnetic circuit design of the valve. Hence, nine valve configurations are considered fo...
متن کاملInfluence of prosthetic heart valve sound on a patient's quality of life.
PURPOSE To elucidate the effects of prosthetic valve sound on a patient's quality of life (QOL). METHODS We compared the valve sounds of ATS, SJM, and Carbomedics (CM) based on assessments by 248 patients who underwent mechanical valve replacements from January 2000 to August 2003 at seven facilities in Japan. We used a self-administered questionnaire for evaluating patients' assessments of v...
متن کاملRight sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملFailure analysis of an intake valve in a gasoline engine
This paper presents a failure analysis on a failed intake valve in a gasoline engine. During an endurance test, an intake valve was broken and caused some damages on the piston. Material examinations (by a light microscope and also a scanning electron microscope) were conducted on the fracture surface of the intake valve shaft. Results showed that no pores or defects could be observed and the m...
متن کاملSpirometric evaluation of pulmonary function in Yazd’s dental laboratory workers in 1398
abstract Introduction: Spirometry is a common device screening in occupational pulmonary disease. Dental laboratory workers usually are exposed to vapor, toxic gases, dust, metallic alloys, acrylics, and stones. Aim of This study was a Spirometric evaluation of the pulmonary function of Yazd’s dental laboratory workers. Method and materials: in this cross-sectional study 37 Yazd’dental tech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia
دوره 13 3 شماره
صفحات -
تاریخ انتشار 2007