Optical properties of poly(2,6-dimethyl-1,4-phenylene oxide) film and its potential for a long-term solar ultraviolet dosimeter.

نویسندگان

  • R A Lester
  • A V Parisi
  • M G Kimlin
  • J Sabburg
چکیده

The optical properties of poly(2,6-dimethyl-1,4-phenylene oxide) (PPO) film have been characterized in order to develop an alternative method for UV dosimetry with a focus on long-term human exposure measurements. The dynamic range of PPO film was found to extend to 2 MJ m(-2) of broadband UV exposure independently of film thickness, providing an exposure range of roughly four summer days at subtropical latitudes. The sensitivity of the film to UV exposure was positively related to film thickness in the 20-40 microm range. Films of 40 microm thickness proved to be the most suitable for long-term human UV exposure measurements. The temperature independence of the response of 40 microm PPO film was established from 1.5 degrees C to 50 degrees C within a dosimeter response uncertainty of 6.5%. Dose-rate independence was also demonstrated within 8% of the mean dosimeter response. The spectral response approximates the CIE erythemal action spectrum between 300 and 340 nm, with a peak response at 305 nm. A large deviation from this action spectrum was observed at shorter wavelengths. Investigation of the angular response in both the azimuth and altitude planes showed a cosine error of less than 6.2% between 0 degrees and 40 degrees, and did not exceed 13.3% at any angle greater than 40 degrees. These results indicate that PPO film satisfies the requirements for use as a UV dosimeter, and may be employed in long-term human exposure measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field calibrations of a long-term UV dosimeter for aquatic UVB exposures.

Various methodologies using a wide range of measurement systems have been employed previously in order to determine the amount of UV that could be incident upon various aquatic organisms in a number of different aquatic locales. Broadband meters and spectroradiometers have been employed extensively to take underwater measurements. However, these measurement campaigns are limited by the fact tha...

متن کامل

Usage of the polyphenylene oxide dosimeter to measure annual solar erythemal exposures.

Poly (2,6-dimethyl-1,4-phenylene oxide) (PPO) film is a useful dosimetric tool for measuring solar UV in underwater and terrestrial environments. However, little is known about how the response of PPO changes with fluctuations in atmospheric ozone and also to seasonal variations. To resolve this issue this article presents a series of long-term in-air solar erythemal response measurements made ...

متن کامل

A novel poly(2,6-dimethyl-1,4-phenylene oxide) with trifunctional ammonium moieties for alkaline anion exchange membranes.

2,4,6-Tri(dimethylaminomethyl)-phenol was synthesized as a trifunctional moiety and incorporated onto poly(2,6-dimethyl-1,4-phenylene oxide) (PPO) to obtain a novel quaternary ammonium functionalized PPO (PPO-TQA). Membranes of the polymer were fabricated and exhibited high conductivity, a low swelling ratio and water uptake.

متن کامل

Synthesis, Characterization and Transport Properties of Novel Ion-exchange Nanocomposite Membrane Containing In-situ Formed ZnO Nanoparticles

A  new  type  of  cation-exchange  nanocomposite  membranes  was prepared  by  in-situ  formation  of  ZnO  nanoparticles  in  a  blend containing  sulfonated  poly  (2,6-dimethyl-1,4-phenylene  oxide)  and sulfonated polyvinylchloride  via  a  simple  one-step  chemical method.  As-synthesized  nanocomposite  membranes were characterized  using  Fourier  transform  infrared  spectroscopy, scan...

متن کامل

Applicability of the polyphenylene oxide film dosimeter to high UV exposures in aquatic environments.

Previous research has proven that the Poly (2,6-dimethyl-1, 4-phenylene oxide) (PPO) dosimeter is capable of receiving both in-air and underwater UV exposures that are significantly greater than those of the more commonly used polysulphone dosimeter, within a range of accuracy close to what would be expected of dosimetric measurements made in-air provided that the necessary calibrations are com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 48 22  شماره 

صفحات  -

تاریخ انتشار 2003