A five-year performance review of field-scale, slow-release permanganate candles with recommendations for second-generation improvements.

نویسندگان

  • Mark Christenson
  • Ann Kambhu
  • James Reece
  • Steve Comfort
  • Laurie Brunner
چکیده

In 2009, we identified a TCE plume at an abandoned landfill that was located in a low permeable silty-clay aquifer. To treat the TCE, we manufactured slow-release potassium permanganate cylinders (oxidant candles) that had diameters of either 5.1 or 7.6 cm and were 91.4 cm long. In 2010, we compared two methods of candle installation by inserting equal masses of the oxidant candles (7.6-cm vs 5.1-cm dia). The 5.1-cm dia candles were inserted with direct-push rods while the 7.6-cm candles were housed in screens and lowered into 10 permanent wells. Since installation, the 7.6-cm oxidant candles have been refurbished approximately once per year by gently scraping off surface oxides. In 2012, we reported initial results; in this paper, we provide a 5-yr performance review since installation. Temporal sampling shows oxidant candles placed in wells have steadily reduced migrating TCE concentrations. Moreover, these candles still maintain an inner core of oxidant that has yet to contribute to the dissolution front and should provide several more years of service. Oxidant candles inserted by direct-push have stopped reducing TCE concentrations because a MnO2 scale developed on the outside of the candles. To counteract oxide scaling, we fabricated a second generation of oxidant candles that contain sodium hexametaphosphate. Laboratory experiments (batch and flow-through) show that these second-generation permanganate candles have better release characteristics and are less prone to oxide scaling. This improvement should reduce the need to perform maintenance on candles placed in wells and provide greater longevity for candles inserted by direct-push.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using slow-release permanganate candles to remove TCE from a low permeable aquifer at a former landfill.

Past disposal of industrial solvents into unregulated landfills is a significant source of groundwater contamination. In 2009, we began investigating a former unregulated landfill with known trichloroethene (TCE) contamination. Our objective was to pinpoint the location of the plume and treat the TCE using in situ chemical oxidation (ISCO). We accomplished this by using electrical resistivity i...

متن کامل

Developing slow-release persulfate candles to treat BTEX contaminated groundwater.

The development of slow-release chemical oxidants for sub-surface remediation is a relatively new technology. Our objective was to develop slow-release persulfate-paraffin candles to treat BTEX-contaminated groundwater. Laboratory-scale candles were prepared by heating and mixing Na(2)S(2)O(8) with paraffin in a 2.25 to 1 ratio (w/w), and then pouring the heated mixture into circular molds that...

متن کامل

Study of the Transition to Instability in Second-Harmonic Generation with Scale Index Method

The emergence of second-harmonic generation (SHG) is a pivotal issue to the development of nano-optical devices and interfaces. Here, we perform a classical analysis of the SHG dynamics with the aim of determining critical values of the electric field. The signals of the SHG process are nonlinear, so it seems reasonable that chaos theory can be a suitable tool to analyze their dynamics. For thi...

متن کامل

Effective Approach to Potassium Permanganate Poisoning: Case Report and Review of Literature

Background: Potassium permanganate (PP) is a highly corrosive and deadly agent with a reported lethal dose of 10 g in adults. In this report, successful treatment of a patient poisoned with three times the lethal dose of PP is presented, and effective and early approach to such emergency toxicologic condition is discussed. Case Presentation:A 24-year-old woman presented to emergency room of our...

متن کامل

Comparison of Positional Release Technique with and without strain-counter strain technique on the pain, neck range of motion in men with active trigger points in upper trapezius muscle

 Aims and background: Trigger points are sensitive points in the skeletal muscle and neck muscles that cause referral pain, decrease the range of motion and muscle soreness. Therefore, the purpose of this study was to compare the effect of the Positional Release Technique with and without strain-counter strain technique on the pain, neck range of motion in men with active trigger points in uppe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemosphere

دوره 150  شماره 

صفحات  -

تاریخ انتشار 2016