One-step chemiluminescent immunoassay of free thyroxin with acridinium-ester-labeled thyroxin evaluated and compared with a two-step radioimmunoassay.

نویسندگان

  • J Y Bounaud
  • M P Bounaud
  • F Begon
چکیده

This new one-step chemiluminescent immunoassay of free thyroxin (FT4) involving a thyroxin-immunoglobulin conjugate labeled with acridinium ester (Magic Lite System; Ciba Corning Diagnostics Corp., Medfield, MA) is rapid (one 1-h incubation), requires two calibrators per run, and takes 10 s per sample for the quantification step. Analytical performances were excellent: within- and between-run CVs of less than 10% in the working range, no significant effect of hemolysis, bilirubin, or lipemia, and no significant interaction between the conjugate and the thyroxin-binding proteins. Magic Lite results (y) correlated well with those obtained by the Sclavo (x) two-step radioimmunoassay (Sclavo, Siena, Italy): y = 1.35x + 1.32 (r = 0.94, n = 267, P less than 0.001, Sxy = 6.29). Clinical sensitivities (diagnostic efficiencies) for hypothyroidism and hyperthyroidism were 0.91 and 0.98 for normal interval limits of 12 and 21.5 pmol/L (95% confidence interval). Magic Lite results in situations where patient therapy, treatment, or unusual conditions can result in a lack of correlation between the clinical status and the FT4 values were qualitatively the same as those obtained by the Sclavo assay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Chemiluminescent labeled-antibody assay for thyroxin in serum, with magnetic separation of the solid-phase.

A chemiluminescent labeled-antibody immunoassay has been developed for measurement of total thyroxin (T4) in serum. Monoclonal antibodies to T4 labeled with a chemiluminescent acridinium ester are used. Serum samples are incubated with the labeled antibodies and a thyroxin-rabbit immunoglobulin conjugate, then reacted with magnetizable particles containing sheep anti-rabbit immunoglobulin. The ...

متن کامل

New one-step enzyme immunoassay for free thyroxin.

This enzyme immunoassay for free thyroxin (FT4) involves simultaneous incubation of sample and thyroxin conjugated to horseradish peroxidase (EC 1.11.1.7) in antibody-coated tubes at room temperature. The test can be performed in 90 min. It is not influenced by variations in concentrations of thyroxin-binding globulin (TBG), thyroxin-binding prealbumin, or albumin. With increased concentrations...

متن کامل

Two new two-step immunoassays for free thyroxin evaluated: solid-phase radioimmunoassay and time-resolved fluoroimmunoassay.

We measured concentrations of free thyroxin (FT4) in serum by using two new two-step FT4 assays--a solid-phase two-step radioimmunoassay. Spectria, and a time-resolved fluoroimmunoassay. Delfia--and compared the results with those by a two-step FT4 assay (RIA-gnost), a one-step FT4 analog assay (Amerlex-M), and FT4 measured after equilibrium dialysis. The new FT4 assays classified 30 hypothyroi...

متن کامل

An evaluation of a fluorescence polarization immunoassay of thyroxin and thyroxin-uptake.

We evaluated the fluorescence polarization immunoassay for total thyroxin (T4) and thyroxin-uptake (T-U) in the Abbott "TDx" Analyzer. Between-assay precision was good when we did once-fortnightly calibration and assayed samples in singleton. Measured T4 concentration was decreased in hemolyzed samples with obvious red coloration and undetectable in severely hemolyzed samples. The T-U assay was...

متن کامل

One-step, labeled-antibody assay for measuring free thyroxin. I. Assay development and validation.

We describe a one-step, labeled-antibody radioassay for measuring free thyroxin (FT4) in serum or plasma, based on a novel principle. FT4 in the sample competes with a gross molar excess (over antibody) of a cross-reactant (L-triiodothyronine, T3), chemically coupled to magnetizable polymer particles, for binding to avid 125l-labeled monoclonal anti-thyroxin antibodies. As in conventional immun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 12  شماره 

صفحات  -

تاریخ انتشار 1988