Variability and repeatability of quantitative, Fourier-domain optical coherence tomography Doppler blood flow in young and elderly healthy subjects.
نویسندگان
چکیده
PURPOSE The purpose of this study was to determine the within-session variability and between-session repeatability of spectral Fourier-domain optical coherence tomography (Doppler FD-OCT) Doppler retinal blood flow measurements in young and elderly subjects. METHODS Doppler FD-OCT blood flow was measured using the RTVue system. One eye of each of 20 healthy young (24.7 ± 2.7 years) and 16 healthy elderly (64.6 ± 5.1 years) subjects was randomly selected, and the pupil was dilated. The double circular scanning pattern of the RTVue was employed. Six Doppler FD-OCT measurements (i.e., each separate measurement comprising an upper and a lower nasal pupil scan) were acquired at each session. Measurements were repeated approximately 2 weeks later. Total retinal blood flow was calculated by summing flow from all detectable venules surrounding the optic nerve head. The coefficient of variation (COV) and coefficient of repeatability (COR) were calculated for each individual. RESULTS The individual COVs for retinal blood flow for young subjects ranged from 0.4% to 20.4% (median 7.5%) and for the elderly subjects ranged from 0.6% to 34.6% (median 9.2%). The group mean CORs for retinal blood flow for young participants were 6.4 μL/min (median 5.91 μL/min, relative to a mean effect 39.8 μL/min) and for elderly subjects were 10.5 μL/min (median 9.2 μL/min, relative to a mean effect 46.4 μL/min). CONCLUSIONS Doppler FD-OCT gave consistent and repeatable blood flow measurements within retinal venules in normal subjects. Considering the individual variation in blood flow measurements, confidence limits for retinal hemodynamics need to be determined on an individual basis.
منابع مشابه
Imaging pulsatile retinal blood flow in human eye.
A functional Fourier domain optical coherence tomography instrument offering spectral Doppler imaging of in vivo pulsatile human retinal blood flow was constructed. An improved phase-resolved algorithm was developed to correct bulk motion artifacts. Spectral Doppler imaging provides complementary temporal flow information to the spatially distributed flow information of the color Doppler image ...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملMeasurement of retinal blood flow in normal Chinese-American subjects by Doppler Fourier-domain optical coherence tomography.
PURPOSE To measure total retinal blood flow (TRBF) in normal, healthy Chinese Americans by using semi-automated analysis of Doppler Fourier-domain optical coherence tomography (FD-OCT) scans. METHODS Two hundred sixty-six normal, healthy Chinese-American participants (266 eyes) were enrolled from The Chinese American Eye Study. All participants underwent complete ophthalmic examination, inclu...
متن کاملPilot study of optical coherence tomography measurement of retinal blood flow in retinal and optic nerve diseases.
PURPOSE To investigate blood flow changes in retinal and optic nerve diseases with Doppler Fourier domain optical coherence tomography (OCT). METHODS Sixty-two participants were divided into five groups: normal, glaucoma, nonarteritic ischemic optic neuropathy (NAION), treated proliferative diabetic retinopathy (PDR), and branch retinal vein occlusion (BRVO). Doppler OCT was used to scan conc...
متن کاملResponse of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography
PURPOSE There is a long-standing interest in the study of retinal blood flow in humans. In the recent years techniques have been established to measure retinal perfusion based on optical coherence tomography (OCT). In the present study we used a technique called dual-beam bidirectional Doppler Fourier-domain optical coherence tomography (FD-OCT) to characterize the effects of 100% oxygen breath...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 55 12 شماره
صفحات -
تاریخ انتشار 2014