Flow disturbances in stent-related coronary evaginations: a computational fluid-dynamic simulation study.

نویسندگان

  • Maria D Radu
  • Aloïs Pfenniger
  • Lorenz Räber
  • Stefano F de Marchi
  • Dominik Obrist
  • Henning Kelbæk
  • Stephan Windecker
  • Patrick W Serruys
  • Rolf Vogel
چکیده

AIMS Angiographic ectasias and aneurysms in stented segments have been associated with late stent thrombosis. Using optical coherence tomography (OCT), some stented segments show coronary evaginations reminiscent of ectasias. The purpose of this study was to explore, using computational fluid-dynamic (CFD) simulations, whether OCT-detected coronary evaginations can induce local changes in blood flow. METHODS AND RESULTS OCT-detected evaginations are defined as outward bulges in the luminal vessel contour between struts, with the depth of the bulge exceeding the actual strut thickness. Evaginations can be characterised cross-sectionally by depth and along the stented segment by total length. Assuming an ellipsoid shape, we modelled 3-D evaginations with different sizes by varying the depth from 0.2-1.0 mm, and the length from 1-9 mm. For the flow simulation we used average flow velocity data from non-diseased coronary arteries. The change in flow with varying evagination sizes was assessed using a particle tracing test where the particle transit time within the segment with evagination was compared with that of a control vessel. The presence of the evagination caused a delayed particle transit time which increased with the evagination size. The change in flow consisted locally of recirculation within the evagination, as well as flow deceleration due to a larger lumen - seen as a deflection of flow towards the evagination. CONCLUSIONS CFD simulation of 3-D evaginations and blood flow suggests that evaginations affect flow locally, with a flow disturbance that increases with increasing evagination size.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Simulation of Laminar Convective Heat Transfer and Pressure Drop of Water Based-Al2O3 Nanofluid as A Non Newtonian Fluid by Computational Fluid Dynamic (CFD)

The convective heat transfer and pressure drop of water based Al2O3 nanofluid in a horizontal tube subject to constant wall temperature condition is investigated by computational fluid dynamic (CFD) method. The Al2O3 nanofluid at five volume concentration of 0.1, 0.5, 1.0, 1.5 and 2 % are applied as a non Newtonian power law and Newtonian fluid with experimentally measured properties of density...

متن کامل

Friction Stir Welding؛ Material Flow؛ Heat Generation؛ Thermal Simulation؛ Poly methyl methacrylate (PMMA)

In this study, the effects of linear and rotational speed of the friction stir welding tool was investigated on the heat generation and distribution at surface and inside of workpiece, material flow and geometry of the welding area of poly methyl methacrylate (PMMA) workpiece. The commercial CFD Fluent 6.4 software was used to simulation of the process with computational fluid dynamic technique...

متن کامل

Multiphase flow and tromp curve simulation of dense medium cyclones using Computational Fluid Dynamics

Dense Medium Cyclone is a high capacity device that is widely used in coal preparation. It is simple in design but the swirling turbulent flow, the presence of medium and coal with different density and size fraction and the presence of the air-core make the flow pattern in DMCs complex. In this article the flow pattern simulation of DMC is performed with computational fluid dynamics and Fluent...

متن کامل

Hemodynamic Changes in Coronary Artery after Stent Implantation Based on Patient-specific Model

Intravascular stents are tubular structures placed into stenotic artery to expand the inside passage and improve blood flow. The mechanical factors affect the restenosis after stenting and image-based simulation has become a popular tool for acquiring information. The aim of this study was to demonstrate quantitatively and qualitatively the hemodynamic changes in coronary artery after stent imp...

متن کامل

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 2014