Quantitative OCT-based longitudinal evaluation of intracorneal ring segment implantation in keratoconus.

نویسندگان

  • Pablo Pérez-Merino
  • Sergio Ortiz
  • Nicolas Alejandre
  • Ignacio Jiménez-Alfaro
  • Susana Marcos
چکیده

PURPOSE To characterize the geometrical properties of keratoconic corneas upon intracorneal ring segments (ICRS) implantation, using custom-developed optical coherence tomography (OCT). METHODS Ten keratoconic corneas were measured pre- and post-ICRS surgery (7, 30, and 90 days). Corneal topographic and pachymetric maps were obtained from three-dimensional (3D) images acquired with OCT, provided with custom algorithms for image analysis, distortion correction, and quantification. The 3D positioning of the ICRS was also estimated longitudinally, relative to the pupil center and iris plane. RESULTS Preoperatively, the average corneal radii of curvature were 7.02 ± 0.54 mm (anterior) and 5.40 ± 0.77 mm (posterior), and the minimum corneal thickness was 384 ± 60 μm. At 90 days, the average corneal radii of curvature were 7.26 ± 0.53 mm (anterior) and 5.44 ± 0.71 mm (posterior), and the minimum corneal thickness was 396 ± 46 μm. ICRS implantation produced a significant decrease of corneal power (by 1.71 ± 1.83 diopters [D] at 90 days). Corneal irregularities (defined by high order Zernike terms of the corneal elevation maps) and the corneal thickness distribution decreased in some patients and increased in others. The 3D ICRS depth matched the planned ICRS depth well (within 23.93 ± 23.49 μm). On average, ICRS showed an overall tilt of -6.8 ± 2.6° (temporal) and -2.1 ± 0.8° (superior) at 7 days. CONCLUSIONS Spectral OCT (sOCT) provided with distortion correction and analysis tools, is an excellent instrument for evaluating the changes produced by ICRS in keratoconic corneas, and for analyzing the 3D ICRS position during the follow up. ICRS produced flattening on the anterior corneal surface, although the benefit for corneal surface regularization varied across patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative OCT-based corneal topography in keratoconus with intracorneal ring segments

Custom high-resolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT) was used to characterize three-dimensionally (3-D) corneal topography in keratoconus before and after implantation of intracorneal ring segments (ICRS). Previously described acquisition protocols were followed to minimize the impact of the motions of the eye. The collected set of images was cor...

متن کامل

Ferrara intracorneal ring segments for keratoconus.

PURPOSE To assess the outcome of Ferrara intracorneal ring segments for keratoconus. SETTING Private practice and university hospital, Porto Alegre, Brazil. METHODS In this retrospective noncomparative interventional case series, 51 keratoconus eyes of 47 patients that had Ferrara intracorneal ring segment implantation were reviewed. Uncorrected visual acuity (UCVA), best spectacle-correcte...

متن کامل

Visual perception changes and optical stability after intracorneal ring segment implantation: comparison between 3 months and 1 year after surgery

PURPOSE To prospectively evaluate intracorneal ring segment (ICRS) implantation on quality of life (QoL) of patients with keratoconus changes and identify factors responsible. METHODS Sixty-nine eyes of 42 keratoconus patients were implanted with the Keraring (Mediphacos, Belo Horizonte, Brazil). Best corrected visual acuity (BCVA), refraction, and steep keratometry were analyzed 3 months and...

متن کامل

Methicillin-Resistant Staphylococcus aureus Acute Keratitis After Intracorneal Ring Segment Implantation

INTRODUCTION The purpose of this study was to report the first case of acute bacterial keratitis produced by methicillin-resistant Staphylococcus aureus after the implantation of two intracorneal ring segments during an uneventful procedure for treating keratoconus in a 13-year-old child. CASE REPORT A patient with grade III keratoconus underwent an implantation of intracorneal ring segments ...

متن کامل

Author’s response to reviews Title: Visual rehabilitation in moderate keratoconus: combined corneal wavefront-guided transepithelial photorefractive keratectomy and high-fluence accelerated corneal collagen cross- linking after intracorneal ring segment implantation Authors:

Title: Visual rehabilitation in moderate keratoconus: combined corneal wavefront-guided transepithelial photorefractive keratectomy and high-fluence accelerated corneal collagen crosslinking after intracorneal ring segment implantation Authors: Hun Lee ([email protected]) David Sung Yong Kang ([email protected]) Byoung Jin Ha ([email protected]) Jin Young Choi ([email protected]) Eung Kweon Ki...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 54 9  شماره 

صفحات  -

تاریخ انتشار 2013