Multiple range imaging camera operation with minimal performance impact

نویسندگان

  • Refael Z. Whyte
  • Andrew D. Payne
  • Adrian A. Dorrington
  • Michael J. Cree
چکیده

Time-of-flight range imaging cameras operate by illuminating a scene with amplitude modulated light and measuring the phase shift of the modulation envelope between the emitted and reflected light. Object distance can then be calculated from this phase measurement. This approach does not work in multiple camera environments as the measured phase is corrupted by the illumination from other cameras. To minimize inaccuracies in multiple camera environments, replacing the traditional cyclic modulation with pseudo-noise amplitude modulation has been previously demonstrated. However, this technique effectively reduced the modulation frequency, therefore decreasing the distance measurement precision (which has a proportional relationship with the modulation frequency). A new modulation scheme using maximum length pseudo-random sequences binary phase encoded onto the existing cyclic amplitude modulation, is presented. The effective modulation frequency therefore remains unchanged, providing range measurements with high precision. The effectiveness of the new modulation scheme was verified using a custom time-of-flight camera based on the PMD19-K2 range imaging sensor. The new pseudo-noise modulation has no significant performance decrease in a single camera environment. In a two camera environment, the precision is only reduced by the increased photon shot noise from the second illumination source.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of portable gamma camera imaging in intraoperative radioguided parathyroid adenoma identification

Novel surgical applications include radioguided procedures in parathyroidectomy operations. In order to investigate the feasibility of usage of the portable gamma camera in parathyroidectomy operations; intraoperative radioguided parathyroidectomy operation was performed in three hyperparathyroidism patients with inconclusive preoperative parathyroid scintigraphy results. Intraoperative portabl...

متن کامل

Determination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera

Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution.  The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...

متن کامل

Computational Photography with Novel Camera Sensors

In this thesis, two computational camera designs are presented. They target two major goals in computational photography. high dynamic range (HDR) imaging and image superresolution (SR). HDR imaging refers to capturing both bright and dark details in the scenes simultaneously. A modulo camera does not get saturated during exposure, enabling HDR photography in a single shot without losing spatia...

متن کامل

Amorphous Silicon Flat Panel Imagers for Medical Application

A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...

متن کامل

An alternative mathematical modeling of the scintillation camera and framework for performance analysis of gamma-ray positioning algorithms

Introduction: Substantive amount of work has been done in modeling and analyzing the scintillation camera system processes including positioning and image formation. The goal of this work is to develop a framework for analyzing performance of nonlinear positioning methods upon construction of a mathematical model of the system. In this study, the photodetector array counts are ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010