SU-E-T-368: Effect of Oblique Beam Incidence On 3D Dose Reconstruction for Small Field IMRT QA.

نویسندگان

  • J Zhang
  • W Laub
چکیده

PURPOSE To compare dose reconstruction accuracy with different oblique beam angles when 2d detector arrays are used for small field IMRT QA. METHODS 2D detector arrays are convenient to use but their low resolution limits the number of sampling points inside small radiation fields. In this study, we demonstrate that with oblique beam incidence, more points can be measured and 3D dose volume can be reconstructed more accurately. QA plans were simulated and measured using four oblique angles: 90 degree (straight incidence), 60 degree, 30 degree, and 15 degree. 3D dose volume was reconstructed based on dose measurements through back-projection and inverse attenuation correction. Total delivering dose was calculated after rotating individual beam doses into actual beam angles. Two IMRT QA devices were used in our study, including a PTW /Octavius phantom and a Delta4 QA device. A spine SBRT plan was chosen as the study case. Gamma passing rate, mean PTV dose, and maximum dose received 2cc of spinal cord were calculated to compare reconstructed dose to original planning dose. Effects of measurement error and detector resolution were also investigated. RESULTS Oblique beam incidence will improve the sampling frequency of dose measurments. When the detector spacing is 10mm, 30 degree is the optimal angle for the Delta4 phantom and 15 degree is the opitmal angle for the PTW/Octavius phantom. Compared with standard straight incidence setup, QA with the optimal angle has 10% higher gamma passing rate (with 2mm/2% criteria) in both simulation and actual measurement. However, oblique incidence didn' t improve QA accuracy consistently when the detector spacing is 5mm. CONCLUSION Oblique incidence can be used to improve IMRT QA accuracy for 2d-array devices which don' t have sufficient spatial resolution for small field measurement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SU-E-T-164: Clinical Implementation of ASi EPID Panels for QA of IMRT/VMAT Plans.

PURPOSE To investigate various issues for clinical implementation of aSi EPID panels for IMRT/VMAT QA. METHODS Six linacs are used in our clinic for EPID-based plan QA; two Varian Truebeams, two Varian 2100 series, two Elekta Infiniti series. Multiple corrections must be accounted for in the calibration of each panel for dosimetric use. Varian aSi panels are calibrated with standard dark fiel...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

3D Analysis of Intensity-Modulated Radiation Therapy Quality Assurance Measurement using a 2D Diode Array

Intensity-modulated radiation therapy (IMRT) quality assurance (QA) is often performed using a 2D device and compares measured and computed fluence maps to determine if a field passes or fails certain dose and position criteria. The effects of a measured deviation to the 3D patient spatial dosimetry and dose volume histogram (DVH) are largely unknown because they cannot be analyzed using commer...

متن کامل

Curtailing patient-specific IMRT QA procedures from 2D dose error distribution

A patient-specific quality assurance (QA) test is conducted to verify the accuracy of dose delivery. It generally consists of three verification processes: the absolute point dose difference, the planar dose differences at each gantry angle, and the planar dose differences by 3D composite irradiation. However, this imposes a substantial workload on medical physicists. The objective of this stud...

متن کامل

dimensional film dosimetry with GAFCHROMIC films for quality assurance and dosimetric verification of 3D conformal radiotherapy in the presence of heterogeneities

Introduction: The presence of heterogeneities such as air-filled cavities in the head and neck treatment fields region, may result in potential dosimetric disagreement because the losses of charged particle equilibrium. Most of treatments planning systems are not able to predict dose distribution of inhomogeneities region accurately. Therefore, dose calculation algorithms need to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 40 6Part16  شماره 

صفحات  -

تاریخ انتشار 2013