Raman and Rayleigh Calibrations of the LHD YAG Thomson Scattering

نویسندگان

  • Ichihiro YAMADA
  • Kazumichi NARIHARA
  • Hiroshi HAYASHI
  • Hisamichi FUNABA
چکیده

We have carried out absolute calibrations of the LHD YAG Thomson scattering system by using Raman scattering and Rayleigh scattering in order to verify the applicability of Rayleigh calibration in the LHD Thomson scattering, and make a comparative study of Raman and Rayleigh calibrations. In the LHD Thomson scattering device, Rayleigh calibration is expected to give more reliable calibration factors. For the Rayleigh calibration, additional Rayleigh channel was installed into 20 polychromators. The other 124 polychromators without Rayleigh channel were calibrated by only Raman scattering. In the Raman calibration, pure gaseous nitrogen was introduced into the LHD vacuum vessel whereas the Rayleigh calibration was made by using air as target gas. The calibration factors obtained from the Raman and Rayleigh calibrations show good agreements. Uncertainties in the calibration factors obtained from the Raman and Rayleigh calibrations are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of 2-D Thomson Scattering Measurement Using Multiple Reflection and the Time-of-Flight of Laser Light

A new two-dimensional Thomson scattering measurement (2-D TS) system has been developed using multiple reflections and time-of-flight (TOF) of laser light. Its new ideas of our 2-D TS system are (1) to reflect YAG laser light for multiple times to cover the whole r − z plane of the ST (Spherical Tokamak) plasma, and (2) to reduce the number of polychromators and detectors using the time delay o...

متن کامل

Study of Cluster Formation and its Effects on Rayleigh and Raman Scattering Measurements in a Mach 6 Wind Tunnel by

Using a frequency-doubled Nd-YAG pulsed laser and a single-intensified CCD camera, Rayleigh scattering measurements have been performed to study the cluster formation in a Mach 6 wind tunnel at NASA Langley Research Center. These studies were conducted both in the free stream and in a model flow field for various flow conditions to gain an understanding of the dependence of the Rayleigh scatter...

متن کامل

Upgraded Calibrations of the Thomson System at Diii-d

The DIII–D Thomson system measures electron density and temperature with eight pulsed ND:YAG lasers along three paths through the plasma vessel. The components of the Thomson system are absolutely calibrated so the measurements can be combined into a single profile from a normalized plasma radius (p) of about 0.1 to the edge of the plasma. A monochromator calibration and opto-electronic calibra...

متن کامل

On-Demand Density Correction Using Steady-State Plasmas in the LHD Thomson Scattering

In order to measure reliable electron densities of fusion plasmas by using Thomson scattering system, both accurate absolute calibration and long-term stability in the system are required. Even if slight misalignment of some optics occurs, it may cause large errors in measured densities. We propose a new method to obtain correction factors to the errors originated from misalignment by using ste...

متن کامل

Collective Thomson Scattering Study Using Gyrotron in LHD

The collective Thomson scattering (CTS) is one of the most promising methods for evaluating the ion velocity distribution function. The study of CTS diagnostic has been started utilizing the gyrotron and antenna/transmission systems installed in LHD for high power local electron heating. One of the high power gyrotrons at 77 GHz is selected as a probing power source and a set of highly focused ...