Risk Factors for Periacetabular Osteolysis and Wear in Asymptomatic Patients with Uncemented Total Hip Arthroplasties

نویسندگان

  • Buster Sandgren
  • Joakim Crafoord
  • Henrik Olivecrona
  • Göran Garellick
  • Lars Weidenhielm
چکیده

Osteolysis is a silent disease leading to aseptic loosening. This has not been studied in a cohort of asymptomatic patients. The aim of this study was to detect factors that might be associated with the development of periacetabular osteolysis and wear around an uncemented cup. We assessed 206 patients with an uncemented cup, measuring wear and periacetabular osteolysis using computed tomography with a median follow-up of 10 years after surgery (range 7-14 years). EQ5D, pain from the hip, and satisfaction were assessed. The association between periacetabular osteolysis and wear, age, gender, activity, BMI, cup type, cup age, positioning of the cup, and surface coating was investigated with a proportional odds model. Wear and male gender were associated with an increased risk for periacetabular osteolysis. There was no association with periacetabular osteolysis for time from operation, patient age, UCLA Activity Score, liner thickness at time of operation, BMI, cup positioning, and type of implant. A thin liner at time of operation is correlated to increased wear. Linear wear rate was 0.18 mm/year and 46 of 206 patients had large periacetabular osteolysis. Asymptomatic patients with these implants should be followed up on a regular basis with a sensitive method such as CT in order to detect complications early.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of wear and periacetabular osteolysis using dual energy computed tomography on a pig cadaver to identify the lowest acceptable radiation dose

OBJECTIVES Computed tomography (CT) plays an important role in evaluating wear and periacetabular osteolysis (PAO) in total hip replacements. One concern with CT is the high radiation exposure since standard pelvic CT provides approximately 3.5 millisieverts (mSv) of radiation exposure, whereas a planar radiographic examination with three projections totals approximately 0.5 mSv. The objective ...

متن کامل

Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear

Osteolysis, which is considered to be a major source of morbidity following total hip joint replacement, has been notoriously difficult to measure accurately, particularly in the acetabular area. In order to study periacetabular osteolysis, specialized software for computerized tomography (CT) scan image analysis has been developed. This software (3D-CT) eliminates metal artifacts, allows three...

متن کامل

Premature wear and osteolysis in an HA-coated, uncemented total hip arthroplasty.

The ABG I cementless hip prosthesis has demonstrated unacceptably high rates of wear and osteolysis in our patients. We performed a retrospective study of 97 hips implanted between 1992 and 1998. Radiographic analysis revealed high rates of wear of the polyethylene liner with marked peri-acetabular osteolysis. Clinical examination indicated that many of these patients were initially asymptomati...

متن کامل

The Usefulness of Three-dimensional Computed Tomography as an Assessment of Periacetabular Osteolysis in Revision Total Hip Arthroplasty

PURPOSE This study was performed to determine the usefulness of three-dimensional computed tomography (3D-CT) in measuring periacetabular osteolysis by comparing the real volume of osteolysis in revision surgery. MATERIALS AND METHODS Twnety-three patients who had undergone revision surgery due to periacetabular osteolysis but not included septic osteolysis and implant loosening. The mean age...

متن کامل

The Result of Revision Total Hip Arthroplasty in Patients with Metallosis Following a Catastrophic Failure of a Polyethylene Liner

BACKGROUND Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014