New Designs of Focussed Air-coupled Ultrasonic Transducer
ثبت نشده
چکیده
The paper describes new developments in air-coupled ultrasonic transducers that can be used to focus energy in air. All transducers to be described are based on a capacitive design, using a rigid backplate and a thin polymer membrane. There are three approaches that can be used to achieve focussing, all of which are described: focussing with a mirror, using curved back-plates, and linear phased arrays. The performance of these transducers is discussed. INTRODUCTION Air-coupled ultrasound has gained popularity recently, because of the non-contact nature of the transduction process. The most common transducers used for air-coupled experiments are based on piezoelectric and electrostatic designs. The first of these, using piezoelectric materials such as PZT, tend to be resonant, and hence require special backing and construction to obtain suitable damping coefficients. In addition, the characteristic impedance of the piezoelectric element is very different to that of air. Hence, a quarter-wavelength thick matching layer at the frequency of interest is thus usually introduced at the front surface. Many types of materials have been tested and found to be useful as the matching layers, but these limit the overall bandwidth. One way of reducing the impedance of the material is to use 1-3 connectivity piezopolymer composites [1], which contain an array of piezoelectric ceramic rods in a polymer filler matrix. These have a wider bandwidth than traditional piezoelectric materials such as PZT. An alternative transducer design is based on the capacitance or electrostatic principle. This has received much interest recently because of the extended bandwidths that can be obtained. These devices are composed of a thin membrane film and a rigid conducting backplate to form a capacitor. Applied voltages cause the membrane to vibrate, and hence generate ultrasound, whereas a change in charge across the membrane can be used for detection. Metallic backplates can be used [2], many employing machined backplates to improve the acoustic properties of the transducer. This type of transducer was found to be very sensitive at high bias voltages when a thin polymer membrane was used [3]. An increase in the device bandwidth requires more careful control of surface features, and hence silicon has been investigated as the backplate material [4,5]. An additional approach is the fully-micromachined device, where the complete structure is fabricated using CMOS technology from a silicon wafer. Typically, such designs use a silicon substrate and a silicon nitride or polysilicon membrane [6]. However, there appears to be relatively little work published on focussed air-coupled ultrasound from capacitive transducers. This paper reviews various types of device that could be used. One approach is to use an external focussing element and a planar transducer. Here we describe the use of off-axis parabolic mirrors. In addition, a curved backplate has been investigated in a conical geometry. These have been investigated for use in situations where a relatively large depth of focus is required. Finally, a cylindrical device has been constructed, which shows interesting features. The following presents a description of the devices, and measurements of the frequency response, resolution and radiated field characteristics. This is then followed by images produced in pulse–echo mode of surface features. CONICAL AIR-COUPLED TRANSDUCERS The conical transducer consisted of a polished brass backplate, retained within a machined aluminium casing, and electrically isolated from the casing with an insulating nylon insert. A cut-away schematic diagram of the transducer is shown in Figure 1. The internal active area of the backplate is in the shape of a truncated (45°) cone, with inner and outer radii of 13mm and 30mm respectively. This was designed to produce a line of focus 34mm in length, starting at a position of z=26mm from the extrapolated internal apex of the cone. After manufacture of the transducer, the backplate was carefully polished by hand to a surface finish of 0.25 μm. It was then washed in acetone and cleaned further with an air jet. A 3.5μm thick Mylar metallised membrane was attached over the backplate, in the presence of an applied bias voltage to reduce the amount of trapped air. Conducting silver paint was used to electrically connect the metallised front face of the film to the aluminium casing. The transducer was driven with wide bandwidth transients from a Panametrics 5055 pulser/receiver, which could also be used as a receiver charge amplifier in pitch-catch mode. The capacitance transducer required a 200V d.c. bias to operate as a receiver, and this was supplied via a power supply and a capacitance de-coupler circuit. This also attracted the membrane to the backplate, enhancing bandwidths in pulse-echo. Waveforms were stored on a Tektronix TDS430A digital oscilloscope, and transferred to a PC for analysis. The transducer was operated in pulse-echo mode, and the received signal in air from the surface of a flat glass block is shown in Figure 2(a), with the surface positioned at the centre of the nominal focal region in air. This shows a wide-bandwidth, well-damped signal at a relatively high-amplitude (50mV pk-pk). The time of flight of the received pulse-echo signal corresponds to a propagation distance of approximately 65mm. The frequency spectrum (Figure 2(b)) demonstrates that the peak response was at just over 0.5MHz. Figure 1 Schematic diagram of the conical transducer Time ( μs) 180 185 190 195 200 205 A m pl itu de (m V ) -30 -20 -10 0 10 20 30 40 Frequency (MHz) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 A m pl itu de (A rb itr ar y) 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 Figure 2 Response of the conical device in pulse-echo from a flat surface The radiated fields of focussed air-coupled transducers was measured by scanning a miniature detector through their fields, using a PC-controlled stage. The results for the conical transducer are shown in Figure 3 for transient excitation. Note that the area where z <20 mm has been shaded black to show the un-scanned area (the scan was initiated at z = 20 mm). As can be seen, there is an extended region of focussing along the transdcuer axis, demonstrating the large depth of field of this device. 0 10 20 30 40 50 60 70 Axial position, Z (mm) -10 -5 0 5 10 R ad ia l p os iti on , X (m m ) Figure 3 Experimental field variations from a conical transducer under transient excitation. CYLINDRICAL TRANSDUCERS An illustration of the cylindrical transducer shown in Figure 4. It consisted of a polished rectangular brass backplate, measuring 19.5 mm wide by 45 mm in length, which was retained within a machined aluminium casing using an insulating nylon insert. An electrical connection was made from the backplate to the centre pin of a BNC connector mounted on the exterior of the device, with the case itself being grounded via the shield contact of this connector. As above, final assembly involved fitting of the membrane, after thorough cleaning by an air jet. A section of the 3.5 μm thick Mylar metallised film, large enough to cover the whole of the front of the device, was fixed in place by gluing around its edge. Electrically conducting silver paint was then used to connect the front metallised surface of the film to the case. This whole procedure was accomplished with an applied d.c. bias of 100 V, to minimise trapped air between the membrane and backplate. Figure 4 The cylindrical air-coupled transducer The transducer was first positioned above a flat polished glass block, with its front face parallel to the surface. It was then carefully aligned to give maximum amplitude of the received signal, so that the focal region was on the surface of the block. Figure 5(a) shows the received waveform. It can be seen that a clean, well-damped signal has been produced. It can also be noted that the time of arrival of the reflected wave was approximately 163 μs, which corresponds to a distance of ∼56.9 mm in air (assuming a velocity of 343.4 ms), hence a distance of 27.95 mm between the transducer and the surface of the block. This is consistent with the designed focal length of the transducer (28 mm). The corresponding frequency spectrum of the waveform is shown in Figure 5(b). It is evident that the transducer has a –6dB bandwidth of approximately 700 kHz, with lower and upper frequency points of 150kHz and 850kHz respectively, and a peak response at ~400 kHz. Time (μs ) 150 155 160 165 170 175 180 Am pl itu de (m V) 40 -20 0 2 0 4 0 6 0 8 0 1 0 0 Frequency (MHz) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 A m pl itu de ( A rb itr ar y)
منابع مشابه
Investigation of the delamination type defects parameters in multilayered GLARE 3 - 3 / 2 composite material using air – coupled ultrasonics technique
Air – coupled ultrasonic investigation possess a great potential for investigation of aerospace composite materials, because it avoids disadvantages caused by immersion or contact techniques. In the work the test sample of the GLARE3-3/2 composite material with artificial delamination type defect was investigated. Numerical and experimental investigations using focussed air – coupled ultrasonic...
متن کاملCHARACTERIZATION OF CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCERS IN AIR USING OPTICAL MEASUREMENTS Sean
Capacitive micromachined ultrasonic transducers (CMUTs) are efficient transmitters and receivers for air-coupled nondestructive evaluation applications [l]. In this paper, we present optical measurements on CMUTs with circular and rectangular membranes. Use of a laser interferometer permits accurate measurement of individual membrane displacements as well as characterization of mode shapes on t...
متن کاملAir Coupled Ultrasonic Inspection of Steel Rubber Interface
This paper describes the investigation for the feasibility of inspection of steel-rocasin rubber specimen used in rocket motor for detection of debond by using air-coupled ultrasonic. A pair of high performance air-coupled transducers was used to generate and receive the high intensity ultrasonic pulses. Probes were placed at the opposite side of the specimen during inspection. It was shown tha...
متن کاملAir-Coupled Low Frequency Ultrasonic Transducers and Arrays with PMN-32%PT Piezoelectric Crystals
Air-coupled ultrasonic techniques are being increasingly used for material characterization, non-destructive evaluation of composite materials using guided waves as well as for distance measurements. Application of those techniques is mainly limited by the big losses of ultrasonic signals due to attenuation and mismatch of the acoustic impedances of ultrasonic transducers and air. One of the wa...
متن کاملAssessment of Ultrasonic NDT Methods for High Speed Rail Inspection
This article reviews some new ultrasonic rail inspection methods emerging in recent years. It focuses on the state of the art for guided wave technologies and their potential use for used for rail inspection. It considers ultrasound transduction options including EMATs, air coupled, pulsed laser and wheel probe guided wave methods. It compares performances in terms of frequency ranges, energy d...
متن کامل