Reproducibility of ERG responses obtained with the DTL electrode

نویسندگان

  • Marc Hébert
  • Vaegan
  • Pierre Lachapelle
چکیده

Previous investigators have suggested that the DTL fibre electrode might not be suitable for the recording of replicable electroretinograms. We present experimental evidence that when used adequately, this electrode does permit the recording of highly reproducible retinal potentials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Dawson, Trick, and Litzkow electrode and contact lens electrodes used in clinical electroretinography.

PURPOSE To determine the reliability of the Dawson, Trick, and Litzkow (DTL) electrode in electroretinographic recordings (ERG) in subjects of all ages, we evaluated ERG responses obtained with the contact lens (CL) and DTL electrodes and estimated a DTL/CL ratio for each sample. METHODS Seventy-nine volunteers aged 2-84 years (79 normal eyes) were recruited for the study. Electroretinographi...

متن کامل

Comparing DTL microfiber and Neuroline skin electrode in the Mini Ganzfeld ERG

BACKGROUND In infant ERG recordings skin electrodes frequently result in a better compliance. In order to assess the quality of such recordings, we compared the recording characteristics of DTL microfiber and Neuroline surface electrodes using a modified ISCEV protocol in the Mini Ganzfeld ERG. METHODS A prospective cohort study on healthy adult subjects was conducted at the Department of Oph...

متن کامل

Evaluation of different recording parameters to establish a standard for flash electroretinography in rodents

Different electrodes and stimulus protocols commonly used for electroretinography in rodent eyes were compared for convenience of use, degree of damage to corneal epithelium, and for magnitude of amplitude, reproducibility, left versus right eye accuracy, and reliability of recorded parameters of the flash electroretinogram (ERG). Adult C57BL/6 pigmented mice and albino Wistar rats were used to...

متن کامل

Validation of a new fiber electrode prototype for clinical electroretinography.

PURPOSE To validate a new fiber electrode prototype for clinical electroretinography (ERG). METHODS A recently developed prototype of a disposable reference-coupled fiber electrode (patent pending Brazilian Institute of Industrial Property # PI0602186-7), including one fiber for corneal signals and a second fiber acting as reference was tested in a group of 20 healthy volunteers (17-31 years;...

متن کامل

Electroretinography in dogs using a fiber electrode prototype

We compared two electroretinography (ERG) electrodes in dogs using ERG standards of the International Society for Clinical Electrophysiology of Vision (ISCEV). Ten healthy Yorkshire terrier dogs (mean age, 2.80 ± 1.42 years; 6 females) weighing 5.20 ± 1.56 kg were evaluated using an ERG system for veterinary use. Dark- and light-adapted ERG responses were recorded using an ERG-Jet electrode and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 39  شماره 

صفحات  -

تاریخ انتشار 1999