Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function.

نویسندگان

  • K Chen
  • D Bandy
  • E Reiman
  • S C Huang
  • M Lawson
  • D Feng
  • L S Yun
  • A Palant
چکیده

The authors developed and tested a method for the noninvasive quantification of the cerebral metabolic rate for glucose (CMRglc) using positron emission tomography (PET), 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function. Dynamic PET data acquired 12 to 48 seconds after rapid tracer injection were summed to identify carotid artery regions of interest (ROIs). The input function then was generated from the carotid artery ROIs. To correct spillover, the early summed image was superimposed over the last PET frame, a tissue ROI was drawn around the carotid arteries, and a tissue time activity curve (TAC) was generated. Three venous samples were drawn from the tracer injection site at a later time and used for the spillover and partial volume correction by non-negative least squares method. Twenty-six patient data sets were studied. It was found that the image-derived input function was comparable in shape and magnitude to the one obtained by arterial blood sampling. Moreover, no significant difference was found between CMRglc estimated by the Patlak method using either the arterial blood sampling data or the image-derived input function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of an image derived input function with MR-defined carotid arteries in FDG-PET human studies using a novel partial volume correction method.

Kinetic analysis of 18F-fluorodeoxyglucose positron emission tomography data requires an accurate knowledge the arterial input function. The gold standard method to measure the arterial input function requires collection of arterial blood samples and is an invasive method. Measuring an image derived input function is a non-invasive alternative but is challenging due to partial volume effects ca...

متن کامل

Noninvasive quantification of cerebral metabolic rate for glucose in rats using 18F-FDG PET and standard input function

Measurement of arterial input function (AIF) for quantitative positron emission tomography (PET) studies is technically challenging. The present study aimed to develop a method based on a standard arterial input function (SIF) to estimate input function without blood sampling. We performed (18)F-fluolodeoxyglucose studies accompanied by continuous blood sampling for measurement of AIF in 11 rat...

متن کامل

Characterization of the image-derived carotid artery input function using independent component analysis for the quantitation of [18F] fluorodeoxyglucose positron emission tomography images Image-derived input function by ICA for FDG-PET

We previously developed a noninvasive technique for the quantification of fluorodeoxyglucose (FDG) positron emission tomography (PET) images using an imagederived input function obtained from a manually drawn carotid artery region. Here, we investigate the use of independent component analysis (ICA) for more objective identification of the carotid artery and surrounding tissue regions. Using FD...

متن کامل

FDG-PET parametric imaging by total variation minimization

Parametric imaging of the cerebral metabolic rate for glucose (CMRGlc) using [(18)F]-fluoro deoxyglucose positron emission tomography is considered. Traditional imaging is hindered due to low signal-to-noise ratios at individual voxels. We propose to minimize the total variation of the tracer uptake rates while requiring good fit of traditional Patlak equations. This minimization guarantees spa...

متن کامل

Measurement of metabolic tumor volume: static versus dynamic FDG scans

BACKGROUND Metabolic tumor volume assessment using positron-emission tomography [PET] may be of interest for both target volume definition in radiotherapy and monitoring response to therapy. It has been reported, however, that metabolic volumes derived from images of metabolic rate of glucose (generated using Patlak analysis) are smaller than those derived from standardized uptake value [SUV] i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism

دوره 18 7  شماره 

صفحات  -

تاریخ انتشار 1998