Subcapital femoral neck fracture following successful trochanteric fracture treatment with a dynamic hip screw: a report of five cases.

نویسندگان

  • Y T Lung
  • W L Kam
  • Y F Leung
  • O M Chung
  • Y L Wai
چکیده

A subcapital femoral neck fracture complicating a healed trochanteric fracture is rare. Such cases are managed in a rather heterogeneous manner, i.e. there exists a mixture of cases treated by either fixed angle devices or dynamic compression screws. We describe 5 patients who developed subcapital femoral neck fractures after healed trochanteric fractures treated with dynamic compression screws. The subjects' clinical data, operative records, and radiographs have been studied retrospectively and the literature reviewed. The risk factors for such a complication include being of advanced age, female, osteoporotic, and having a small femoral head and neck, and a basicervical type of fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

شکستگی ساب کاپیتال گردن فمور بعد از جوش خوردگی شکستگی اینترتروکانتریک

Abstract We report a 71 year-old patient with intertrochanteric fracture who had been managed with DHS and her healed fracture complicated by a subcapital femoral neck fracture. A subcapital femoral neck fracture complicating a healed intertrochanteric fracture is rare but catastrophic event. Such cases are managed in a hetereogenous manner, i.e. there exists a mixture of cases tr...

متن کامل

Treatment of femoral fracture through the sliding screw portal following fixation of the femoral neck fracture.

The authors report a case of secondary femoral fracture through the sliding hip screw portal following fixation of the femoral neck fracture. The femoral neck and subtrochanteric fracture was successfully treated by superimposing a trochanteric stabilization plate (TSP) onto the regular sliding hip screw.

متن کامل

A Comparative Study Of The Management Of Fracture Neck Femur By Dynamic Hip Compression Screw With Derotation Screw Versus Three Cancellous Screws

Background: Intracapsular fractures of neck femur have always presented a great challenge to orthopaedics surgeons and remain in many ways the unsolved fracture as far as treatment and results are concerned. Methods: Cases included in this study are transcervical and subcapital fracture neck femur in patients less than 60 yrs of age managed in Sir JJ Hospital, Mumbai -08. Results: Fracture type...

متن کامل

Dynamic Hip Screw for the Treatment of Femoral Neck Fractures: A Prospective Study with 96 Patients

UNLABELLED Objectives. To study the correlation between avascular necrosis and the demographics, time elapsed from fracture to surgery, quality of reduction, Garden classification, and the position of the screw following use of the dynamic hip screw (DHS) in the treatment of subcapital neck fractures. Methods. A prospective study of 96 patients with subcapital neck fractures was carried out in ...

متن کامل

Concomitant ipsilateral subcapital and intertrochanteric fractures of the femur: a case report

INTRODUCTION We report the case of an unusual combination of concomitant subcapital and intertrochanteric fractures of the hip in a patient after a motorcycle accident. To the best of our knowledge, there is no previous report in the literature of these conditions as a result of high energy trauma or of the treatment used. CASE PRESENTATION A 36-year-old Caucasian man was admitted with this r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2007