Magnetic resonance elastography: feasibility of liver stiffness measurements in healthy volunteers at 3T.

نویسندگان

  • L Mannelli
  • E Godfrey
  • M J Graves
  • A J Patterson
  • P Beddy
  • D Bowden
  • I Joubert
  • A N Priest
  • D J Lomas
چکیده

AIM To demonstrate the feasibility of obtaining liver stiffness measurements with magnetic resonance elastography (MRE) at 3T in normal healthy volunteers using the same technique that has been successfully applied at 1.5 T. METHODS AND MATERIALS The study was approved by the local ethics committee and written informed consent was obtained from all volunteers. Eleven volunteers (mean age 35 ± 9 years) with no history of gastrointestinal, hepatobiliary, or cardiovascular disease were recruited. The magnetic resonance imaging (MRI) protocol included a gradient echo-based MRE sequence using a 60 Hz pneumatic excitation. The MRE images were processed using a local frequency estimation inversion algorithm to provide quantitative stiffness maps. Adequate image quality was assessed subjectively by demonstrating the presence of visible propagating waves within the liver parenchyma underlying the driver location. Liver stiffness values were obtained using manually placed regions of interest (ROI) outlining the liver margins on the gradient echo wave images, which were then mapped onto the corresponding stiffness image. The mean stiffness values from two adjacent sections were recorded. RESULTS Eleven volunteers underwent MRE. The quality of the MRE images was adequate in all the volunteers. The mean liver stiffness for the group was 2.3 ± 0.38 kPa (ranging from 1.7-2.8 kPa). CONCLUSIONS This preliminary work using MRE at 3T in healthy volunteers demonstrates the feasibility of liver stiffness evaluation at 3T without modification of the approach used at 1.5 T. Adequate image quality and normal MRE values were obtained in all volunteers. The obtained stiffness values were in the range of those reported for healthy volunteers in previous studies at 1.5 T. There was good interobserver reproducibility in the stiffness measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo determination of hepatic stiffness using steady-state free precession magnetic resonance elastography.

OBJECTIVE The objective of this study was to introduce an magnetic resonance elastography (MRE) protocol based on fractional motion encoding and planar wave acquisition for rapid measurements of in vivo human liver stiffness. MATERIALS AND METHODS Vibrations of a remote actuator membrane were fed by a rigid rod to the patient's surface beneath the right costal arch resulting in axial shear de...

متن کامل

Magnetic resonance elastography of liver in healthy Asians: normal liver stiffness quantification and reproducibility assessment.

PURPOSE To determine normal liver stiffness values evaluated with magnetic resonance elastography (MRE) in healthy normal Asian volunteers and assess its reproducibility. MATERIALS AND METHODS Liver stiffness was evaluated with MRE in 41 healthy Asians (23 females, 18 males; mean age, 41.8 years, and mean body mass index [BMI], 23.4 kg/m(2) ) on a 1.5T clinical scanner. The correlations betwe...

متن کامل

Quantification of aortic stiffness using MR elastography and its comparison to MRI-based pulse wave velocity.

PURPOSE To determine the correlation in abdominal aortic stiffness obtained using magnetic resonance elastography (MRE) (μ(MRE)) and MRI-based pulse wave velocity (PWV) shear stiffness (μ(PWV)) estimates in normal volunteers of varying age, and also to determine the correlation between μ(MRE) and μ(PWV). MATERIALS AND METHODS In vivo aortic MRE and MRI were performed on 21 healthy volunteers ...

متن کامل

Validity study of Spin Echo EPI based hepatic MR Elastography at 3.0T

Introduction: Magnetic Resonance Elastography (MRE), a noninvasive technique for quantitatively assessing the mechanical properties of soft tissues (1), is very promising for diagnosing hepatic fibrosis by detecting elevated hepatic shear stiffness (2-4). Typically MRE is performed on 1.5T MR systems as these are commonly available in the clinical practice. MR imaging at higher field strengths,...

متن کامل

Preliminary Comparison of Multi-scale and Multi-model Direct Inversion Algorithms for 3T MR Elastography

PURPOSE To elucidate whether any differences are present in the stiffness map obtained with a multiscale direct inversion algorithm (MSDI) vs that with a multimodel direct inversion algorithm (MMDI), both qualitatively and quantitatively. MATERIALS AND METHODS The MR elastography (MRE) data of 37 consecutive patients who underwent liver MR elastography between September and October 2014 were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical radiology

دوره 67 3  شماره 

صفحات  -

تاریخ انتشار 2012