Evaluation of myocardial mechanics with three-dimensional speckle tracking echocardiography in heart transplant recipients: comparison with two-dimensional speckle tracking and relationship with clinical variables.
نویسندگان
چکیده
AIMS Two-dimensional speckle-tracking echocardiography (2D-STE) is limited by its inability to track tissue motion in three dimensions. This is particularly relevant in heart transplant recipients, in whom marked translational motion of the transplanted heart is present. We aimed to compare 3-dimensional (3D)- and 2D-STE-derived strain parameters, and to identify clinical features associated with myocardial mechanics in transplant recipients. METHODS AND RESULTS In 36 heart transplant recipients, global and regional left-ventricular (LV) longitudinal and circumferential strain (LSt and CSt), and radial displacement (RDisp) were obtained by 3D- and 2D-STE, and their results were compared. 3D-STE deformation from a subset of transplant recipients with preserved ejection fraction was compared with a control group of 25 subjects matched by gender, age, history of hypertension, and ejection fraction. Associations between global LSt and CSt and clinical, echocardiographic, and haemodynamic parameters in transplant recipients were investigated. 3D-STE yielded lower magnitude of global LSt compared with 2D-STE (-13 ± 3 vs. -16 ± 3%, P < 0.001). The inferolateral wall was a source of variation between 3D- and 2D-STE both for LSt and CSt. Inferolateral wall 3D-STE-derived RDisp was greater than that observed in control subjects (7.4 ± 1.2 vs. 6.5 ± 1.7 mm, P = 0.03), while anteroseptal RDisp was lower than controls (4.2 ± 1.0 vs. 7.3 ± 1.6 mm, P < 0.001). Multiple regression analysis demonstrated that 3D-STE-derived LSt was independently associated with NYHA class (P < 0.001), while 2D-STE-derived LSt was not. CONCLUSION Examination of LV mechanics by 3D- and 2D-STE deformation parameters in heart transplant recipients yields significantly discordant results. 3D-STE-derived LSt is independently associated with NYHA class, suggesting a clinically important relationship between functional status and myocardial mechanics.
منابع مشابه
Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)
The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...
متن کاملFunction and mechanics of the left ventricle: from tissue Doppler imaging to three dimensional speckle tracking.
One of the most common indications in echocardiography is the evaluation of left ventricular function. The traditional measurement of ejection fraction is based upon tracing the left ventricular borders and calculating left ventricular volumes using geometric assumptions. Now, with the introduction of three-dimensional echocardiography, the evaluation of left ventricular function is easier to c...
متن کاملPhysiological basis in the assessment of myocardial mechanics using speckle-tracking echocardiography 2D. Part II
In this paper, the authors attempt to concisely present the anatomical and pathophysiological bases as well as the principles for echocardiographic evaluation of mechanical aspects of cardiac function based on speckle tracking method. This technique uses a phenomenon involving the formation of characteristic image units, referred to as speckles or acoustic markers, which are stable during cardi...
متن کاملThree-Dimensional Speckle-Tracking Echocardiographic Monitoring of Acute Rejection in Heart Transplant Recipients.
OBJECTIVES This study assessed the use of 3-dimensional (3D) speckle-tracking echocardiography for noninvasive monitoring and diagnosis of acute rejection in heart transplant recipients. METHODS Fifteen heart transplant recipients underwent 32 endomyocardial biopsies; echocardiography was performed within 3 hours before biopsy. Twenty-four biopsies (acute rejection-negative group) showed grad...
متن کاملClinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy
Cardiac resynchronisation therapy (CRT) can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 14 12 شماره
صفحات -
تاریخ انتشار 2013