Comparison of QIAGEN automated nucleic acid extraction methods for CMV quantitative PCR testing.
نویسندگان
چکیده
We examined the effect of nucleic acid extraction methods on the analytic characteristics of a quantitative polymerase chain reaction (PCR) assay for cytomegalovirus (CMV). Human serum samples were extracted with 2 automated instruments (BioRobot EZ1 and QIAsymphony SP, QIAGEN, Valencia, CA) and CMV PCR results compared with those of pp65 antigenemia testing. Both extraction methods yielded results that were comparably linear and precise, whereas the QIAsymphony SP had a slightly lower limit of detection (1.92 log(10) copies/mL vs 2.26 log(10) copies/mL). In both cases, PCR was more sensitive than CMV antigen detection, detecting CMV viremia in 12% (EZ1) and 21% (QIAsymphony) of antigen-negative specimens. This study demonstrates the feasibility of using 2 different extraction techniques to yield results within 0.5 log(10) copies/mL of the mean value, a level that would allow for clinical comparison between different laboratory assays.
منابع مشابه
Automated Nucleic Acid Extraction Systems for Detecting Cytomegalovirus and Epstein-Barr Virus Using Real-Time PCR: A Comparison Study Between the QIAsymphony RGQ and QIAcube Systems
BACKGROUND Cytomegalovirus (CMV) and Epstein-Barr virus (EBV) are increasingly important in immunocompromised patients. Nucleic acid extraction methods could affect the results of viral nucleic acid amplification tests. We compared two automated nucleic acid extraction systems for detecting CMV and EBV using real-time PCR assays. METHODS One hundred and fifty-three whole blood (WB) samples we...
متن کاملComparison of two nucleic acid extraction and testing systems for HCMV-DNA detection and quantitation on whole blood specimens from transplant patients.
Quantitative detection of human cytomegalovirus (HCMV) DNA on whole blood is currently the primary choice for virological monitoring in transplant patients and for determining the appropriate antiviral strategy, however specific issues of variability remain in terms of extraction methods, amplification efficiency, and variability. This study compared the performance characteristics of two nucle...
متن کاملTechnology for automated, rapid, and quantitative PCR or reverse transcription-PCR clinical testing.
BACKGROUND PCR-based assays can improve clinical care, but they remain technically demanding and labor-intensive. We describe a new instrument, the GeneXpert, that performs automated nucleic acid isolation, reverse transcription, and fluorescence-based quantitative PCR in approximately 35 min. METHODS Yield and integrity of RNA isolated on the GeneXpert were compared with Qiagen-based extract...
متن کاملEvaluation of real-time PCR laboratory-developed tests using analyte-specific reagents for cytomegalovirus quantification.
Viral load testing for cytomegalovirus (CMV) has become the standard for the diagnosis of infection and monitoring of therapy at many transplant centers. However, no viral load test has been approved by the FDA. Therefore, many laboratories rely on laboratory-developed assays. This study evaluated the performance characteristics of two real-time PCR tests developed using the artus CMV analyte-s...
متن کاملNucleic acid extraction from formalin-fixed paraffin-embedded cancer cell line samples: a trade off between quantity and quality?
BACKGROUND Advanced genomic techniques such as Next-Generation-Sequencing (NGS) and gene expression profiling, including NanoString, are vital for the development of personalised medicines, as they enable molecular disease classification. This has become increasingly important in the treatment of cancer, aiding patient selection. However, it requires efficient nucleic acid extraction often from...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of clinical pathology
دوره 133 4 شماره
صفحات -
تاریخ انتشار 2010