Introduction to the Two-Wire Transmitter & the 4-20mA Current Loop
ثبت نشده
چکیده
Prior to the widespread adoption of electrical and electronic controls, buildings often used pneumatic control systems. Large and powerful compressors drove 3psi to 15psi pneumatic signals throughout a plant and these pneumatic lines connected to pneumatically controlled valves and pneumatically controlling valves in order to drive proportional controls and actuators throughout the building, all powered from compressed air. Air pressure at 3psi served as the “live-zero” and 15psi represented 100%. In this way, the more modern 4-20mA signal standard emulated the earlier 3-15psi pneumatic controls. Any pressure below 3psi was considered “dead zero” and an alarm condition. Some installations still use pneumatic control today. Modern I/P converters (current-to-pressure transducers) are available to convert the 4-20mA control loops to common pneumatic ranges, such as 3-15psi, 118psi, 3-27psi, and 6-30psi.
منابع مشابه
A Novel Data Compression Technique for 420 Ma Current Loop Transmitters
This paper presents a new data compression method for current loop transmitters. In this method, the 4-20 mA current domain is divided into some equal pieces that are used for distinct data domain with a constant relative resolution, resulting in widening the signal span. This technique eliminated the need for high resolution ADC’s or DAC’s in communication of 4-20mA current loop signals. Furth...
متن کاملIndustrial Acceleration Sensing Transmitter Using Capacitive MEMS Accelerometer
This paper presents the overall design of an industrial vibration transmitter using Micro Electro Mechanical System (MEMS) capacitive accelerometer. It describes the accelerometer sensor interfacing circuit, rms-to-dc converter and voltage to current loop converter circuit design, calibration procedure and mounting methods. The industrial vibration transmitter output can be customized to obtain...
متن کاملDesign of HART modem on AVR microcontroller for Smart Transmitter
The majority of smart field devices installed worldwide today are HART-enabled. The HART (Highway Addressable Remote Transducer) Protocol is the global standard for sending and receiving digital information across analog wires between smart devices and control or monitoring system. It is a bi-directional communication protocol that provides data access between intelligent field instruments and ...
متن کاملCoupling Effects and Performance of Loran Transmitter Antennas
It is known that if a conductor resides in the neighboring of an antenna with a small distance relative to the wavelength, it induces a reverse current on the conductor. This paper involves the unavoidable coupling effects on some common types of LF antennas, due to the large wavelength in this frequency band. In particular, after some discussions about top-loaded antennas, the coupling effect ...
متن کاملCampbell (MAXREFDES4#): 16-Bit High-Accuracy 4-20mA Input Isolated Analog Front End (AFE) - Sub-System Board - Maxim
This document explains how the Campbell (MAXREFDES4#) subsystem reference design meets the higher resolution and isolation needs of industrial control and industrial automation applications. Hardware and firmware design files as well as FFTs and histograms from lab measurements are provided. Introduction In industrial control and industrial automation applications, high-resolution data converte...
متن کامل