Correction: Application and Evaluation of Interactive 3D PDF for Presenting and Sharing Planning Results for Liver Surgery in Clinical Routine
ثبت نشده
چکیده
The legends for S1 File and S2 File are incorrectly switched. Please view S1 File and S2 File with their correct legends below.
منابع مشابه
Application and Evaluation of Interactive 3D PDF for Presenting and Sharing Planning Results for Liver Surgery in Clinical Routine
BACKGROUND & OBJECTIVES The Portable Document Format (PDF) is the de-facto standard for the exchange of electronic documents. It is platform-independent, suitable for the exchange of medical data, and allows for the embedding of three-dimensional (3D) surface mesh models. In this article, we present the first clinical routine application of interactive 3D surface mesh models which have been int...
متن کاملThree-Dimensional Color Doppler Ultrasonography Study of Normal Liver Vascular Pattern in Dog
Objective- To create three-dimensional model of the dog's liver vessels by using threedimensionalcolor Doppler ultrasonography which can be used for surgery planning,tumor detecting, transplantation, and other diagnostic or treatment project.Design- Descriptive studyAnimals- 6 mixed breed dog, 1.6-1.7 years old, 18-20 kg weightProcedures- The liver was found by two-dimensional scan initially th...
متن کاملHepaVision2 – A software assistant for preoperative planning in living-related liver transplantation and oncologic liver surgery
HepaVision2, a user friendly software application for preoperative planning based on CT images in liver surgery is presented. It is intended for both, evaluation of potential donors in living-related liver transplantation and planning of oncologic resections. The planning takes into account the patient’s individual anatomy allowing for fully automatic calculation of individual resection proposa...
متن کاملThe Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose
Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...
متن کاملI-44: 3D Ultrasonography of Ovarian Tumors
A prospective study was conducted at the OB/GYN department of Kasr El Eini hospital, Cairo University from Jan 2000 - Oct 2002. The study included 51 patients in the age group between 40-70 years (including pre and post menopausal women). All patients were subjected to following after taking a consent from each patient: Complete clinical evaluation; including history taking and clinical examina...
متن کامل