Computational analysis of aortic hemodynamics during total and partial extracorporeal membrane oxygenation and intra-aortic balloon pump support.

نویسندگان

  • Maria Vittoria Caruso
  • Vera Gramigna
  • Attilio Renzulli
  • Gionata Fragomeni
چکیده

PURPOSE The extracorporeal membrane oxygenation (ECMO) is a temporary, but prolonged circulatory support for cardiopulmonary failure. Clinical evidence suggests that pulsed flow is healthier than non pulsatile perfusion. The aim of this study was to computationally evaluate the effects of total and partial ECMO assistance and pulsed flow on hemodynamics in a patient-specific aorta model. METHODS The pulsatility was obtained by means of the intra-aortic balloon pump (IABP), and two different cases were investigated, considering a cardiac output (CO) of 5 L/min: Case A - total assistance - the whole flow delivered through the ECMO arterial cannula; Case B - partial assistance - flow delivered half through the cannula and half through the aorta. Computational fluid dynamic (CFD) analysis was carried out using the multiscale approach to couple the 3D aorta model with the lumped parameter model (resistance boundary condition). RESULTS In case A pulsatility followed the balloon radius change, while in case B it was mostly influenced by the cardiac one. Furthermore, during total assistance, a blood stagnation occurred in the ascending aorta; in the case of partial assistance, the flow was orderly when the IABP was on and was chaotic when the balloon was off. Moreover, the mean arterial pressure (MAP) was higher in case B. The wall shear stress was worse in ascending aorta in case A. CONCLUSIONS Partial support is hemodynamically advisable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prophylactic Intra-Aortic Balloon Pump Before Ventricular Assist Device Implantation Reduces Perioperative Medical Expenses and Improves Postoperative Clinical Course in INTERMACS Profile 2 Patients.

BACKGROUND Although intra-aortic balloon pump (IABP) is sometimes used before cardiac surgery to achieve better outcome in high-risk patients, the clinical impact of prophylactic IABP support before left ventricular assist device (LVAD) implantation in patients with worsening hemodynamics was unknown. METHODSANDRESULTS We enrolled 22 patients with worsening hemodynamics who had received IABP ...

متن کامل

Mechanical circulatory support in acute cardiogenic shock

Cardiogenic shock complicates about 5% to 8% of all admissions for acute myocardial infarction, and despite advancement in treatment over the past 50 years, mortality remains unacceptably high. Management with vasoactive agents after revascularization can have its limitations and thus mechanical circulatory support is often initiated. Intra-aortic balloon pumps (IABPs) are the devices most comm...

متن کامل

Temporary Mechanical Circulatory Support: A Review of the Options, Indications, and Outcomes

Cardiogenic shock remains a challenging disease entity and is associated with significant morbidity and mortality. Temporary mechanical circulatory support (MCS) can be implemented in an acute setting to stabilize acutely ill patients with cardiomyopathy in a variety of clinical situations. Currently, several options exist for temporary MCS. We review the indications, contraindications, clinica...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Percutaneous Mechanical Circulatory Support Devices in Cardiogenic Shock.

Despite a high rate of early revascularization and use of intra-aortic balloon pump counterpulsation therapy, the prognosis of patients with cardiogenic shock has remained poor. In the hopes of improving outcomes, clinicians are increasingly turning to percutaneous left and right mechanical circulatory support devices. Until recently, the evidence base for these devices had consisted only of ob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta of bioengineering and biomechanics

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 2016