Intensity modulation delivery techniques: "step & shoot" MLC auto-sequence versus the use of a modulator.

نویسندگان

  • S X Chang
  • T J Cullip
  • K M Deschesne
چکیده

Two intensity modulation radiotherapy (IMRT) delivery systems, the "step & shoot" multileaf collimator (MLC) auto-sequence and the use of an intensity modulator, are compared with emphasis on the dose optimization quality and the treatment irradiation time. The intensity modulation (IM) was created by a dose gradient optimization algorithm which maximizes the target dose uniformity while maintaining dose to critical structures below a set tolerance defined by the user in terms of either a single dose value or a dose volume histogram curve for each critical structure. Two clinical cases were studied with and without dose optimization: a three-field sinus treatment and a six-field nasopharyngeal treatment. The optimization goal of the latter case included the sparing of several nearby normal structures in addition to the target dose uniformity. In both cases, the target dose uniformity initially improved quickly as the IM level increased to 5, then started to approach saturation when the MLC technique was used. In the absence of the both space and intensity discreteness intrinsic to the MLC technique, the modulator technique produced greater tumor dose uniformity and normal structure sparing. The latter showed no systematic improvement with increasing IM level using the MLC technique. For the sinus tumor treatment of 2 Gy the treatment irradiation time of the modulator technique is no more than that of the conventional treatment. For the MLC technique the irradiation time increased rapidly from 4.4 min to 12.4 min as the IM level increased from 2 to 10. Both clinical cases suggested that an IM level of 5 offered a good compromise between the dose optimization quality and treatment irradiation time. We showed that a realistic photon source model is necessary for dose computation accuracy in the MLC-IM treatments.

منابع مشابه

Investigation of Freedom-Degrees impact on Modulation of Radiation

Introduction: Nowadays tendency to apply more degrees of freedom in high-tech radiotherapy systems, and consequent complex process to optimize dose calculation and delivery algorithms, is a challenge of radiation therapy optimization. Faster MLC speed, dose rate, Gantry angle variation, and other degrees, which have been utilized in IMRT, IMAT, VMAT, improved modulation of inte...

متن کامل

A model for the control of multileaf collimator and related inverseplanning

A new approach for the inverse treatment planning in radiation therapy with the multileaf colli-mator (MLC) technique is presented. The application of the MLC-techniques requires an algorithm for the computation of the positions or velocities of leaves as a function of time such that the prescribed dose in the patient space is obtained. First the intensity distribution in the treatment space is...

متن کامل

Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system

An inverse treatment planning (ITP) module on a commercial treatment planning system (TPS) (Helax AB, Uppsala, Sweden) is being used for an in-house clinical trial for treatment of nasopharyngeal cancer with contralateral parotid sparing. Intensity modulated radiation therapy (IMRT) fields are delivered by step and shoot multileaf collimator (MLC) with a DMLC enabled Varian 2300 CD (Varian Asso...

متن کامل

Validation of dynamic MLC-controller log files using a two-dimensional diode array.

Intensity-modulated radiation therapy (IMRT) delivered with multi-leaf collimator (MLC) in the step-and-shoot mode uses multiple static MLC segments to achieve intensity modulation. For typical IMRT treatment plans, significant numbers of segments are delivered with monitor units (MUs) of much less than 10. Verification of the ability of the linear accelerator (linac) to deliver small MU segmen...

متن کامل

Dosimetric and qualitative analysis of kinetic properties of millennium 80 multileaf collimator system for dynamic intensity modulated radiotherapy treatments.

The aim of this paper is to analyze the positional accuracy, kinetic properties of the dynamic multileaf collimator (MLC) and dosimetric evaluation of fractional dose delivery for the intensity modulated radiotherapy (IMRT) for step and shoot and sliding window (dynamic) techniques of Varian multileaf collimator millennium 80. Various quality assurance tests such as accuracy in leaf positioning...