Quantification of Surface Wetting in Plate-like Structures via Guided Waves

نویسندگان

  • Honglei Li
  • Jennifer E. Michaels
  • Sang Jun Lee
  • Thomas E. Michaels
چکیده

Ultrasonic guided wave methods are being widely explored for inspection of large structural areas using a sparse array of surface-mounted transducers. However, structural health monitoring (SHM) with guided waves can be problematic because variable operational conditions can significantly affect the measured ultrasonic signals. Although homogeneous temperature variations have been well-researched and successful compensation algorithms developed, few studies have considered distributed surface wetting. This paper reports results from an experimental investigation of the effects of surface wetting on guided wave signals recorded from a spatially distributed array affixed to a stiffened aluminum plate. Droplets of water were applied to the plate in a random and increasing manner until almost forty percent of the plate was wet, and the percent surface area covered at each increment of wetting was independently measured via digital photographs of the plate surface. Ultrasonic guided wave signals resulting from a broadband chirp excitation were recorded from all transducer pairs in between increments of wetting. Root mean squared errors as compared to the dry plate are calculated from these signals at multiple frequencies to investigate the efficacy of quantifying the degree of surface wetting. This study is a first step in the process of assessing and addressing the effects of distributed surface wetting on the performance of a guided wave SHM system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental and numerical study of delamination detection in a WGF/epoxy composite plate using ultrasonic guided waves and signal processing tools

Reliable damage detection is one of the most critical tasks in composite plate structures. Ultrasonic guided waves are acknowledged as an effective way of structural health mo...

متن کامل

Peri-Elastodynamic Simulations of Guided Ultrasonic Waves in Plate-Like Structure with Surface Mounted PZT

Peridynamic based elastodynamic computation tool named Peri-elastodynamics is proposed herein to simulate the three-dimensional (3D) Lamb wave modes in materials for the first time. Peri-elastodynamics is a nonlocal meshless approach which is a scale-independent generalized technique to visualize the acoustic and ultrasonic waves in plate-like structure, micro-electro-mechanical systems (MEMS) ...

متن کامل

Damage detection and structural health monitoring of ST-37 plate using smart materials and signal processing by artificial neural networks

Structural health monitoring (SHM) systems operate online and test different materials using ultrasonic guided waves and piezoelectric smart materials. These systems are permanently installed on the structures and display information on the monitor screen. The user informs the engineers of the existing damage after observing signal loss which appears after damage is caused. In this paper health...

متن کامل

Guided wave damage characterization via minimum variance imaging with a distributed array of ultrasonic sensors

Guided wave imaging with a distributed array of inexpensive transducers offers a fast and cost-efficient means for damage detection and localization in plate-like structures such as aircraft and spacecraft skins. As such, this technology is a natural choice for inclusion in condition-based maintenance and integrated structural health management programs. One of the implementation challenges res...

متن کامل

Simulation and Measurement of Ultrasonic Waves in Elastic Plates Using Laser Vibrometry

The propagation of Lamb waves in elastic plates is analyzed both numerically and experimentally. A Scanning Laser Doppler Vibrometer (SLDV) is here used to detect and visualize transient waveforms propagating in an elastic plate at low ultrasonic frequencies. The waves are excited by a piezoelectric crystal glued to the plate surface and actuated by sinusoidal pulses of varying frequency. The p...